Loading ...
Loading ...
Loading ...
19
Suggested wire length relative to strain relief
Route power cord through strain relief in the back of the terminal
box. Remove the ground connector screw on the raised oor
inside the box and place it through the ring terminal of the green
ground wire of power cord. Reattach and tighten the ground
connector screw to the raised oor of the box.
Select UL Listed/CSA Approved power cord for the Dishwasher.
Power Cord Ki
t
Kit typically includes power cord, metallic strain relief,grommet.
(Whirlpool Part Number Cord Kit - Straight - W11365011
Cord Kit - Right Angle - W11365014)
To connect wires with ring terminals, remove the screws from the
terminal block, place the screw through the ring terminals, and
reattach screws back into the terminal block.
To connect wires without ring terminals, remove the screws from
the terminal block, push the wire ends under the screw heads, and
tighten the screws.
NOTE: Pre-tinned wires should not be used when connecting to
the terminal block.
Tighten strain relief screws to secure cord.
Place wires inside terminal box. Replace the cover by inserting
the hooks of the terminal cover into the slots in the oor of the
terminal box and sliding the cover tight against the back wall
where wires come in. Make sure wires are tucked inside the box
and not pinched by the cover.
Put the terminal box back on the crossbar and push to the right
so terminal box snaps into the plastic side member.
NOTES:
Once the terminal box has been remounted on the dishwasher,
tuck any excess length or slack over nearby components to
help keep them off the oor.
Route cord out the rear of the dishwasher so that it does not
touch dishwasher motor or lower part of dishwasher tub.
Do not plug cord into an outlet until instructed to do so.
A maximum of 2 power cord supply conductors (12 AWG
largest size) plus 1 grounding conductor are permitted in the
terminal box.
IMPORTANT: NO ADDITIONAL CONNECTIONS OTHER THAN
DISHWASHER POWER CONNECTION ARE TO BE MADE INSIDE
THE DISHWASHER TERMINAL BOX.
Ro
ut
e
po
we
r
co
rd
t
hr
ou
gh
s
tr
ai
n
re
li
ef
i
n
th
ba
ck
f
th
e
te
rm
al
21. Connect ground wire
22. Connect remaining wires
Wiring conguration
23. Secure cord or wire on strain relief
Terminal
box cover
24. Reinstall terminal box cover and wires
4
1
/2"
(114.3 mm)
0.75" - 1"
(19 mm - 25 mm)
Ground
wire
Ground
screw
Washer
Ground connector
screw
White wire
White wire
Black wire
Black wire
Ground wire
Loading ...
Loading ...
Loading ...