Thru-The-Wall Installation
NOTE: Consult local building codes prior to
instal/ation, or a qualified carpenter.
Carefully measure and cut an opening with the
following dimensions. See FIGS. 1 and 2.
Select Wall Location
WIDTH "X" = 24-1/4" plus twice the
thickness of flaming material used.
This air conditioner has a slide-out chassis, so it
can be installed through an outside wall up to 7"
(178 ram) thick. IMPORTANT: Side louvers must
never be blocked.
NOTE: All parts needed for Thru-The-Wall
Installation are provided, except a wood frame,
shims, and 10 wood screws (#10-1" long
minimum (25 ram). Select a wall surface that:
1. does not support major structural loads such
as the frame construction at ends Of windows,
and under truss-bearing points, etc.
2. does not have plumbing or wiring inside.
3. is near existing electrical oudets, or where
another outlet can be installed.
4. faces, and is not blocked to the area to be
cooled.
5. allows unblocked airflow from rear sides and
end (outside) of installed air conditioner.
BPrepare Wall
,
Prepare wall in frame construction (including
brick and stucco veneer). Working from inside
the room, End wall stud nearest the center of
area where air conditioner will be installed (by
sounding wall, or by magnetically Ending
nails).
2. Cut or knock out a hole on each side of center
stud.
3. Measure between inside edges of every other
stud as shown in FIG. 1.
i
I
I
FIG. I
(8.6 cm)
HEIGHT "Y" = 15-1/4" plus twice the
thickness of flaming material used.
Y
X
UP TO
7"
.
Build a wooden sleeve with the INSIDE
dimensions of 24ol/4" in width and 15-1/4" in
height. Frame depth should be the same as
wall thickness. Fill in the space from the
opening to the studs with wood spacers, as
shown.
5. Nail frame to spacers with front flush with
arywaU.