Installation Manual 9
Installation of Indoor, Outdoor Unit
ENGLISH
Outdoor unit
1. If an awning is built over the unit to prevent di-
rect sunlight or rain exposure, make sure that
heat radiation from the condenser is not re-
stricted.
2. Ensure the unit is unobstructed, allow proper
space on all sides according to the arrows
and distance measurements in the figures.
3. Do not place animals and plants in the path of
the warm air.
4. Take the air conditioner weight into account
and select a place where noise and vibration
are minimum.
5.
Select a place so that the warm air and sound
from the air conditioner does not disturb
neighbors.
6. Place that can sufficiently endure the weight
and vibration of the outdoor unit and where
even installation is possible.
7. Place that has no direct influence of snow or
rain.
8. Place with no danger of snowfall or icicle drop.
9. Place without weak floor or base such as de-
crepit part of the building or with a lot of snow
accumulation.
Rooftop Installations:
If the outdoor unit is installed on a roof structure,
be sure to level the unit. Ensure the roof struc-
ture and anchoring method are adequate for the
unit location. Consult local codes regarding
rooftop mounting.
more than
700 (27 9/16)
more than
300 (11 13/16)
more than
600 (23 21/32)
more than
300 (11 13/16)
more than
600 (23 21/32)
Unit:mm(inch)
more than 300
(11 13/16)
more than 300
(11 13/16)
Unit:mm(inch)