To connect a PC to the display’s RS-232
port, you must use a straight-through RS-232
cable where pins 2 (RX) and 3 (TX) are not
reversed at one end.
If there is no data to be sent, then it is not
necessary to send the parameter signal.
If multiple commands are transmitted, make
sure to wait for the response for the first
command to come from the display before
sending the next command. Normally the
sent data byte will be returned as an answer.
In case of an error the next signals will be
returned:
RESPONSE: 70h = MODE ERROR
71h = TEM ERROR
72h = FORMAT ERROR
Command Parameters
These remote control commands are available to
send to the display using RS-232.
Item Cmd Data Details
Read 80 81-A7 Reads the
displays current
settings for
command 81
thru A7
Volume 81 01-64H
Set between 01-64H
Power On/Off 83 00-01 00=Off, 01=On
Brightness 85 01-64H
Contrast 86 01-64H
V-Size 87 01-64H
V-Position 88 01-64H
H-Size 89 01-64H
H-Position 8A 01-64H
Color 8E 01-64H
Tint 8F 01-64H
Sharpness 90 01-64H
Input Select 91 00-07
00=TV, 01=AV1,
02=AV2, 03=AV3,
04=Component 1
05=Component 2
06=RGB,
07=DVI
Recall 92 00 00=Initiate a recall
Mute On/Off 95 00-01 00=Off 01=On
PanelKey Lock 96 00-01 00=Off 01=On
Language 97 00-02 00=English,
01=French,
02=Spanish
Color Temp 98 00-03 00=High, 01=Mid,
02=Low,
03=6500D
Bass 9A 01-64H
Treble 9B 01-64H
Balance 9C 01-64H