10
2009 Electrolux Home Products, Inc. All rights reserved.
Operating Instructions
(continued)
DRAINAGE:
Fig. 23
SWING OPERATION:
When you turn on the unit, the louver will swing and stop at a certain angle. You
can press the SWING button to let the louver swing automatically. Press the
SWING button again while you want the louver stop at desired angle.
CHECK FILTER FEATURE:
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more
efficient operation. The filter indicator will illuminate after 250 hours of operation.
To reset after cleaning the filter, press the "Filter"
button and the light will go off.
FAULT CODE:
Operating Instructions
During the dehumidifying mode, you will need a garden hose (sold
separately) to drain the condensate from the unit.
Remove the rubber stopper from the hose connector, then screw on a
garden hose to the connector as shown on fig 23.
The hose may then:
A. Discharge into a drain that is lower than the unit.
B. Be connected to a condensate pump (sold separately).
Remove the
supplied rubber
stopper
Garden hose
SLEEP OPERATION:
Note: This feature is unavailabe under FAN or DRY modes.
In this mode the selected temperature will increase by 2 °F 30 minutes after the mode
is selected. The temperature will then increase by another 2 °F after an additional 30
minutes. This new temperature will be maintained for 7 hours before it returns to the
originally selected temperature. This ends the "Sleep" mode and the unit will continue to
operate as originally programmed. The "Sleep" mode program can be cancelled at any
time during operation by again pressing the "Sleep" button.
temperature display. Use the same way as above to set the delay start timing by pressing
TIMER ON button. To cancel the timer setting, simply tap TIMER ON or TIMER OFF button
to change the timing to 0.0.
C. During cooling mode, please replace the rubber stopper
to the hose connector to reach the maximum performance.
If the display reads "AS" , the room temperature sensor has failed. Contact your Authorized
Frigidaire Service Center.
If the display reads "ES" , the evaporator temperature sensor has failed. Contact your
Authorized Frigidaire Service Center.
If the display reads "E4" , the display panel communication has failed. Contact your
Authorized Frigidaire Service Center.
If the display reads "P1" , bottom tray is full.
Carefully move the unit to a drain location, remove
the bottom drain plug and let the water drain away. Restart the machine until the "P1" symbol
disappears.
If error repeats, call for service.
SELECTING FAN SPEED:
You can select the desired fan speed, by pressing the FAN SPEED button. The fan
speed will change in the sequence as the drawing on the left.
After choosing the fan speed as "AUTO", “LOW”, “MED” or “HIGH”, the
corresponding fan speed indicator light will illuminate. Under AUTO, Heat, Dry
mode, you can not select the fan speed.
AUTO LOW
MEDHIGH
Loading ...
Loading ...
Loading ...