Installation information
16
Climate class
The appliance is designed for use within
a certain climate range (ambient tem-
peratures) and should not be used out-
side this range. The climate range of the
appliance is stated on the data plate in-
side the appliance.
Climate
class
Room temperature
SN 50°F to 90°F / 10°C to 32°C
N 60°F to 90°F / 16°C to 32°C
ST 60°F to 100°F / 16°C to
38°C
T 60°F to 109°F / 16°C to
43°C
Operating in a room which is too cold
will cause the compressor to turn off for
too long, causing the internal tempera-
ture in the appliance to rise, resulting in
damage.
Risk of damage.
In environments with high humid-
ity, condensation may appear on the
external surfaces of the appliance.
This condensate can cause corrosion
on external appliance panels.
To prevent this, it is advisable to in-
stall the appliance in a dry and/or air-
conditioned room with sufficient ven-
tilation.
After installation, make sure that the
appliance door closes properly, that
the specified ventilation gaps are ad-
hered to, and that the appliance is in-
stalled in accordance with these in-
stallation instructions.
Installation notes
Load-bearing capacity of the niche
floor
The floor of the space where the appli-
ance is to be installed must be flat and
level.
It must be made from strong, rigid ma-
terial.
The appliance is extremely heavy when
fully loaded, and the floor it stands on
must be able to bear its weight. If nec-
essary, seek the advice of an architect
or structural engineer.
When fully loaded, the weight of the ap-
pliance is about:
F 2461 Vi, F 2471 Vi 633 lbs
(287 kg)
F 2661 Vi, F 2671 Vi 765 lbs
(347 kg)
Door hinging
The appliance is supplied with a fixed
hinge. The door hinge cannot be
changed.
Adjoining cabinetry/units
The appliance is screwed to the adjoin-
ing cabinetry/units to the side and
above. For this reason, it is essential
that all cabinets/units are fixed to the
ground and/or wall.