INSTALL 3/4 FLEXIBLE CONDUIT (cont.)
BEFORE MAKING ELECTRICAL
CONNECTIONS
Note to Electrician: The power leads supplied
with this appliance are UL-recognized for
connection to large gauge household wiring.
The insulation of these leads is rated
at temperatures much higher than the
temperature rating of household wiring.
The current carrying capacity of a conductor is
governed by the wire gauge and also the
temperature rating of the insulation around
the wire.
Aluminum Wiring – WARNING: IMPROPER
CONNECTION OF ALUMINUM HOUSE WIRING
TO THE COPPER LEADS CAN RESULT IN
SERIOUS PROBLEMS.
Attach copper wires to aluminum wiring using
special connectors designed and UL-listed for
joining copper to aluminum. Follow the
connector manufacturer’s recommended
procedure closely.
Service Loop – Leave a loop in the wires to the
cooktop so that the cooktop can be lifted 12
inches without having to disconnect the wiring.
Power Supply
Leads
Anti-Short
Bushing
Conduit
ELECTRICAL CONNECTIONS
17
18
ELECTRICAL REQUIREMENTS*
Model # Voltage Frequency KW
JP989 120/240V 60Hz 8.8KW
120/208V 60Hz 6.7KW
*For reference only. Verify with product rating
plate.
Feed the power
supply leads
through the
conduit; be sure to
leave enough
length to properly
connect these
leads to the
cooktop power
leads.
Thread the leads
through an anti-
short bushing and
firmly seat the
bushing in the end
of the conduit.
Feed the leads
through the hole
in the wire
compartment.
As local codes
permit purchase a
listed conduit
connector suitable
for the size
conduit. Insert the
conduit through
the connector and
attach it to the
cover. Allow
enough slack to
easily attach the
wires to the
cooktop.
Note: Do not
install the cooktop
without a listed
conduit connector.
The conduit
connector should
be installed before
reinstalling the
wiring cover.
When complete,
reinstall the wire
compartment
cover.
25
Bushing (Fully Seated)
INSTALL 3/4 FLEXIBLE CONDUIT
18
Remove the screws holding
the wire compartment cover
and remove the cover.