Rinnai Australia 10 RCE-470/670 TRE
Specifications: See back cover of this instruction.
UNPACKING
Never lift the heater out of the carton by top louvres.
Check for damage, if unit is damaged contact supplier or Rinnai for advice.
BEFORE USING THE HEATER
Check unit supplied is correct for gas type in your area.
Refer to local Gas Authority for confirmation of gas type if in doubt.
Check room size and ventilation
This heater must not be installed in a room
smaller than:
The AVENGER 25TRE must not be in a
room smaller than 62.5 m
3
The CAPELLA 18TRE must not be in a
room smaller than 45.0 m
3
Fixed ventilation must conform to local regulations.
Number and position of vents is for illustrative purposes only. For more information on
ventilation, please refer to our Rinnai Web Site www.rinnai.com.au
DO NOT install in a bedroom or bathroom.
The bayonet plug on the factory fitted flexible hose simply plugs into your bayonet fitting.
The control panel is located on the top of the appliance, basic controls are also located on the
remote control.
For the AVENGER - H x W x D must equal or exceed 62.5 m
3
- for example: if room size is L 5.2 m x W 5.0 m x H 2.4 m the volume will be 62.4 m
3
For the CAPELLA - H x W x D must equal or exceed 45.0 m
3
- for example: if room size is L 4.5 m x W 4.2 m x H 2.4 m the volume will be 45.4 m
3
This heater must not be installed where
curtains or other combustible materials could
come into contact with it. In some cases
curtains may need restraining.
Other clearances are shown in the diagram.
This heater is not designed to be built in.
Width
Depth
Height
HEATER
O
N
/
O
F
F
S
E
T
50mm
750mm
50mm
50mm
50mm
The above diagram shows the clearances required
around this heater whilst in operation.
CUSTOMER OPERATING INSTRUCTIONS