Loading ...
Loading ...
Loading ...
123
Although bright spots or dark spots may appear on the screen, this
is a unique characteristic of liquid crystal displays, and it does not constitute or
imply a machine defect.
NOTE
Phenomenon Cases not involving a machine defect
Reference
page
The signal from
HDMI OUT is
not output in the
external device.
Check if PROJECTOR is set in OPTION - SERVICE -
HDMI OUT RESOLUTION.
Set EXTERNAL DEVICE in the menu above.
If the signal is not output yet, check the supported
resolution of the external device.
93
The signal from
HDMI OUT is
not output in
other connected
projectors.
Check if EXTERNAL DEVICE is set in OPTION -
SERVICE - HDMI OUT RESOLUTION.
Set PROJECTOR in the menu above.
93
When the
projector is
connected to
the network, it
powers off and
on as described
below.
Powers off
POWER
indicator blinks
in orange a few
times
Goes into
standby mode
Disconnect the LAN cable and check that the
projector is working properly.
If this phenomenon occurs after connecting to the
network, there may be a loop between two Ethernet
switching hubs within the network, as explained below.
- There are two or more Ethernet switching hubs in a
network.
- Two of the hubs are doubly connected by LAN cables.
- This double connection forms a loop between the two
hubs.
Such a loop may have an adverse effect on the projector
as well as the other network devices.
Check the network connection and remove the loop by
disconnecting the LAN cables such that there is only one
connecting cable between two hubs.
Troubleshooting
Phenomena that may be easy to be mistaken for machine defects (continued)
Loading ...