Please note: T6 and hood switch o, to indicate alarm reset is done.
The reset of the Grease Filter and Charcoal Filter is performed using the
same key. If both lters alarms are active, the reset procedure will reset
the counter one by one, with priority to the Charcoal.
Activating the carbon lter saturation indicator
Please note: This must be done with the extraction motor switched o.
This indicator is usually deactivated – press and hold T3 and T7
simultaneously to activate the function: Both will lightup to indicate
activation.
To deactivate the function, press and hold the same buttons again:
Both will ash briey and then switch o to indicate deactivation.
T7. MAIN LIGHT ON/OFF
Press to switch the hob lights on or o.
TECHNICAL DATA
Height (cm) Width (cm) Depht (cm) Ø of exaust tube (cm)
62-114 59,8 45,5 15
62-114 89,8 45,5 15
CLEANING AND MAINTENANCE
CLEANING
• Do not use steam-cleaning equipment.
• Disconnect the appliance from the mains.
Important: do not use corrosive or abrasive detergents. If any such
products unintentionally come into contact with the appliance, clean
the appliance immediately with a damp cloth. Do not use alcohol.
• Clean the surfaces with a damp cloth. If it is very dirty, add a few
drops of washing-up detergent to the water. Finish o with a dry
cloth.
Important: do not use abrasive sponges or metallic scrapers or
scourers. Over time, these can ruin the enamel surfaces.
• Use detergents specically designed for cleaning the appliance
and follow the manufacturer's instructions.
Important: clean the lters at least once a month to remove oil and
grease residue.
MAINTENANCE OF THE GREASE FILTERS
This must be cleaned once a month (or when the lter saturation
indication system - if envisaged on the model in possession - indicates
this necessity) using non aggressive detergents, either by hand or in the
dishwasher, which must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease lter may discolour slightly,
but this does not aect its ltering capacity.
Pull out the handle to remove the lter.
Once the lter has been washed and left to dry, proceed in reverse
order to ret the lter.
ACTIVE CARBON FILTER (FOR MODELS WITH FILTERING
INSTALLATION ONLY)
The carbon lter must be washed once a month in a dishwasher at the
highest temperature, using a normal detergent for dishwashers. You
are advised to wash the lter on its own.
After being washed, the lter must be dried in the oven at 100°C for 10
minutes in order to reactivate it.
Replace the lter every 3 years.
Assembling the carbon lter:
1. Remove the grease lter.
2. Remote the lter support frame by turning the knobs 90°.
3. Assemble the carbon lter in the support frame.
Follow the above steps in reverse order to replace the lter support
frame and the grease lter.
REPLACING THE LAMPS
The hood is equipped with an LED lighting system.
LEDs ensure excellent illumination, have a service life up to 10 times
longer than traditional bulbs, and oer up to 90% energy savings.
Note: For replacement LED, please contact the Technical After-sales Service
Centre.
* Available only on certain models
Loading ...