Adjust the air pressure at recommended operating
pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm
2
)
according to the length of nails and the hardness of
workpiece.
The correct air pressure is the lowest pressure which will
do the job. Using the Nailer at a higher than required air
pressure unnecessarily over stresses the Nailer.
LOADING NAILS
WARNING
When loading nails into Nailer,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Nailer pointed downward.
<NR83A5 / NR83A5 (S)>
(1) Pull the nail feeder back until it latches
Nail Feeder
(2) Insert nail strips one by one from above the magazine.
Two strips can be loaded at one time.
Nail Strip
Magazine
(3) Press the stop lever and slide the nail feeder forward
until it contacts the nail strip.
Nail Feeder
Stop Lever
NOTE:
Quietly push the Nail Feeder against the nail.
If the Nail Feeder is released from backward the
magazine and bumped against the nail, the
connecting plastic of the nail can be damaged.
Use nail strip at least 5 nails remaining.
Set heads of nails overlapped as shown in the below
gure.
Ensure that the head of tail nail is set under the nail
stopper of nail feeder.
Tail Nail
Nail Stopper
The Nailer is now ready to operate.
Removing the nails:
WARNING
Disconnect air hose from Nailer when
removing nails from the magazine.