MAKE GAS CONNECTION - U.S.A. AND
CANADA
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Connect gas supply to dryer
1.
A
B
Non-ared
male tting
Flared
male tting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound on
threads of all non-ared male ttings. If exible metal tubing is
used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe-joint
compound resistant to action of propane gas. Do not use
TEFLON
®†
tape.
Plan pipe tting connection
2.
A. 3/8" exible gas connector
B. 3/8" dryer pipe
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-are adapter tting
A combination of pipe ttings must be used to connect dryer to
existing gas line. Recommended connection is shown. Your
connection may be different, according to supply line type, size,
and location.
Open shut-off valve
3.
A
B
Open valve
Closed valve
Open shut-off valve in supply line; valve is open when handle is
parallel to gas pipe. Then, test all connections by brushing on
an approved noncorrosive leak-detection solution. Bubbles will
show a leak. Correct any leaks found.
®
TEFLON is a registered trademark of Chemours.