Loading ...
Loading ...
Loading ...
10
Remove terminal block cover
2.
Remove hold-down screw and terminal block cover.
POWER SUPPLY CORD CONNECTION
Power Supply Cord Strain Relief
Attach power supply cord strain
relief
1.
A
B
C
D
Remove the screws from a 3/4" (19 mm) UL Listed strain relief.
Put the tabs of the two clamp sections (C) into the hole below the
terminal block opening (B) so that one tab is pointing up (A) and
the other is pointing down (D), and hold in place. Tighten strain
relief screws just enough to hold the two clamp sections (C)
together.
Attach power supply cord strain
relief
2.
Put power supply cord through the strain relief. Be sure that the
wire insulation on the power supply cord is inside the strain relief.
The strain relief should have a tight t with the dryer cabinet and
be in a horizontal position. Do not further tighten strain relief
screws at this point.
If your outlet looks like this:
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to “4-Wire Power Supply Cord
Connection”.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to “3-Wire Power Supply Cord
Connection.”
4-wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
4-wire receptacle
(NEMA type 14-30R)
4-prong plug
Spade terminals with
upturned ends
Ring terminals
B
A
E
Prepare to connect neutral
ground wire and neutral wire
1.
Remove center terminal block screw (B). Remove neutral ground
wire (E) from external ground conductor screw (A).
Loading ...
Loading ...
Loading ...