Installing the dryer.
Rough-In Dimensions
Dryer MUST be exhausted outside (outdoors,
not beneath the mobile home) using metal
ducting that will not support combustion. Metal
ducting must be 4 (10.16 cm) in diameter with
no obstructions. Rigid metal duct is preferred.
If dryer is exhausted through the floor, the
exhaust system must NOT terminate beneath
the mobile home. Termination MUST be
securely fastened to the mobile home structure.
When installing a gas dryer into a mobile home,
a provision must be made for outside make-up
air. This provision is to be not less than twice the
area of the dryer exhaust outlet.
Gas dryers MUST be fastened to the floor
using Mobile Home Installation Kit Pub.
No. 14-D346-33.
See the Exhaust System Requirements section
for other important venting information.
Installation MUST conform to current
Manufactured Home Construction & Safety
Standard (which is a Federal Regulation Title
24 CFR—Part 32–80) or, when such standard
is not applicable, with American National
Standard for Mobile Homes, ANSI/NFPA
No. 501B.
The dryer is designed for use under ANSI Z 21.5.1.
6
5
4
3
2
1
Mobile Home Installation
26 7/8
(68.3 cm)
47 1/2
(120.7 cm)
43 5/8
(110.7 cm)
2 9/16
(6.5 cm)
13 1/2
(34.4 cm)
36
(91.5 cm)
Door open
90˚
4 3/8
(11.1 cm)
Optional
vent knockout
27
(68.6 cm)
Electrical connection
3/8 (0.96 cm) Dia.
gas pipe
1 (2.54 cm)
3 3/4
(9.5 cm)
3 3/4
(9.5 cm)
REAR VIEW
SIDE VIEW
Correct
Incorrect
Do
Do
Do
Don’t
Don’t
Don’t
Servicing – Consideration must be given to provide adequate clearances for installation and servicing.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation (verify proper operation after servicing/installation).
12