14 / EN
Range Hood / User Manual
6 
Problem Possible cause Solution
The extractor fan cea-
ses to function.
The kitchen hood feed cable is
not connected to the network.
There is no electrical current in
the network.
Connect feed cable to the network.
Check that the network has electrical
current.
Insufficient suction
power.
Did not set to the right speed
and/or air outlet being blocked.
If the kitchen hood is set up for recircula-
tion, check that the charcoal filter is still
effective.
If the kitchen hood is set up for extrac-
tion, check that the ducting and outlets
are not blocked.
The kitchen is adequately vented to allow
the entry of fresh air.
Hood has switched off
during operation.
The safety cut-out device has
been tripped.
Turn off the hood and then wait for the
device to reset.
If the hood has been installed below the
heights indicated in the installation inst-
ructions, the motor will cut-out frequently
which may damage the hood.
The lamps do not light
up.
The lamps are burnt out.
The lamps are loose.
Change the lamps.
Tighten the lamps.
Oil leakage. One-way valve and air ventila-
tion entrance not tightly sealed.
Leakage from the connection of
U-shaped section and cover.
Seal with glue on the one-way valve.
Seal with soap or paint on U-shaped
section.
Hood shakes during
operation.
The filter is damaged.
The body or motor tightly hung.
Replace the filter as a damaged filter
causes shaking.
Lock the motor tightly or fix the body
tightly, respectively.
Loading ...
Loading ...
Loading ...