Owner Manual AIR PURIFIERS
HPA090 series

HPA100 series, HPA200 series, HPA300 series

This model air purifier incorporates a 2-stage cleaning system to help clean the air that passes through the filter in the unit (Fig. 1).

Stage 1: Odor Reducing Pre-Filter
Stage 2: True HEPA Filter that captures particles as small as 0.3 microns or larger
The True HEPA Filters and Odor Reducing Pre-Filter are supplied within the air purifier. New air purifiers have their filters wrapped to ensure purity, and are labeled to help identify the proper replacement filter. (Type R True HEPA Filter; Type A Odor Reducing Pre-Filter or A Household Gas & Odor Reducing Pre-Filter)
) on the front grille to release it from the unit and pull the grille toward you to remove it (see Fig. 2). Grasp the sides of the filter frame near its top end and pull outward. Repeat for the second and third filter if applicable.
) secure in place.This product earned the ENERGY STAR rating by meeting strict energy efficiency guidelines set by the U.S. EPA. The U.S. EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product.
Portable air purifiers are more effective in rooms where all doors and windows are closed. In general, it is recommended that you run your air purifier while you are at home to clean the air.


) to toggle through the setting options. A blue LED light will illuminate the selected setting: Germ, General Clean or Allergen.
) for power cleaning or fast odor reduction.
). The Turbo LED will illuminate. TAPPING the Turbo icon (
) again will return the air purifier to the previous cleaning setting. To shut OFF, tap the Power symbol (
) until the air purifier shuts off.The Timer Option (
) allows you to select how long the air purifier will run before it automatically shuts off. There are three pre-set run times: 2, 4, and 8 hours. Do not use this option if you want the unit to run continuously.
).
The Dimmer Option (
) allows you to adjust the brightness of the LED displays on the control panel (Fig. 6). You may wish to adjust the brightness depending on the room where the unit is placed. The unit always turns on with the brightness on HIGH.

To adjust brightness:
) once to dim the lights to LOW.
) twice and it will shut the lights OFF. (the air purifier will not shut off).
) a third time will return the brightness to HIGH.These air purifier models each have two electronic filter checks to remind you when to check and replace the True-HEPA filters and the Odor Reducing PreFilters based on the air cleaner’s hours of use.
When the True HEPA filter(s) and/or the Pre-Filter need to be replaced, the “Check Filter” or “Check Pre-Filter” light will illuminate (Fig. 7).

You should periodically check these filters. Depending on operating conditions, the True-HEPA filters should be replaced every 12 months, and the Odor Reducing Pre-Filters every 3 months, especially if there have been heavy odors and particles in the home.
To RESET Either Electronic Filter Check:
After you have replaced the appropriate filter(s) the “Check Filter or “Check Pre-Filter” light will remain on until it is reset. With the unit powered on, press the lighted button and hold for approximately 2 seconds until the light turns off. The electronic filter check is now reset. Depending on individual usage (environment and hours used), you may need to replace filters more or less frequently.
NOTE: If you change the Pre-Filter or Filter before the Electronic Filter Check lights are illuminated, it is possible to re-set the light indicators. With the unit plugged in, but NOT powered on, press and hold each button individually for at least 5 seconds. This will illuminate the indicator light. After the light turns on, individually press and hold the “Check Filter” or “Check Pre-Filter” button until each light goes off. At this point, the filter indicator will be re-set to it’s original “clean” status.
These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent upon the concentration of contaminates going through the system. High concentrations of contaminates such as dust, pet dander and smoking will reduce the useful performance of the filter.
NOTE: None of the filters are washable. Do not immerse them in water.
The odor reducing pre-filter not only helps reduce odors, but also helps capture large airborne particles that enter the grille. This Pre-Filter should be replaced every 3 months, as it will become covered with particles and fibers that will reduce filtration performance.
We recommend that you clean the air purifier at least once every 3 months and before extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier.
DO NOT USE WATER, WAX POLISH, OR ANY CHEMICAL SOLUTION.
If your Air Purifier will not be used for more than 30 days, we recommend that you:
My Air Purifier is starting to make noise and the air output is less. What’s wrong?
The filters may be dirty. High amounts of contaminates can block the pores in the filter and stop the air from moving through it. Replace the Filters.
How long should I run my Air Purifier?
In general, the unit will be most effective when doors and windows are closed. It is recommended that you run your air purifier while you are at home to clean the air.
Can I wash any of the filters in my Air Cleaner?
No. Washing either filter will ruin it.
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Air Purifier With Any Solid-State Speed Control Device.