8English
Switch off the device before performing
any work on the device.
Remove the mains plug.
Have all checks and work on electrical
parts performed by an expert.
The motor (suction turbine) does
not start up.
No electrical voltage present.
1. Check the socket and the power
supply fuse.
2. Check the mains cable and the
mains plug of the device.
The motor circuit breaker has tripped.
1. Allow the motor to cool down.
2. Check the suction hose, the contain-
er and the exhaust outlet for a block-
age.
3. Switch the device on.
4. If the motor circuit breaker trips
again, cease operation and contact
Customer Service.
The suction power decreases.
Nozzle, suction hose or suction pipe
clogged.
1. Check the nozzle, the suction hose
and the suction pipe and clean if
necessary.
The filter is dirty.
1. Clean the filter.
Technical data
Subject to technical modifications.
Electrical connection
Mains voltage V 460
Phase ~ 3
Power frequency Hz 60
Nominal power W 630
Protection class IP 55
Protection class I
Power protection (slow-
blowing)
A16
Device performance data
Container capacity gal/m
(l)
5.3
(20)
Air quantity CFM
(l/s)
103
(48.6)
Vacuum kPa
(mbar)
7 (70)
Suction hose connec-
tion
in
(mm)
2.1
(50)
Dimensions and weights
Typical operating
weight
kg 25
Length x width x height mm 570 x
625 x
498
Ambient conditions
Ambient temperature
(max.)
°C +5 -
+40
Determined values in acc. with EN
60335-2-69
Hand-arm vibration val-
ue
m/s
2
<2.5
K uncertainty m/s² 0.2
Sound level L
pA
dB(A) 65
K uncertainty
pA
dB(A) 2