5 Maintenance
Descaling the machine
The ENA builds up deposits of limescale over time
and automatically prompts you to descale it when
necessary. The degree of calcification depends on
the hardness of your water.
E If you use a CLARIS Blue filter cartridge and
this is activated, you will not be prompted to
descale.
J CAUTION
If the descaling agent comes into contact with the
skin or eyes, this can cause irritation.
TAvoid contact with the skin or eyes.
TRinse off the descaling agent with clean
water. Should you get any descaling agent in
your eye, see a doctor.
CAUTION
If the wrong descaling agent is used, the machine
could be damaged and/or traces could be left
behind in the water.
TUse only original JURA maintenance
products.
CAUTION
If the descaling operation is interrupted, there may
be damage to the machine.
TAllow the descaling programme to run to
the end.
CAUTION
If the descaling agent comes into contact with
sensitive surfaces (e.g. marble), damage cannot be
ruled out.
TClean up any splashes immediately.
E The descaling programme lasts approxi-
mately 40minutes.
E JURA descaling tablets are available from
specialised dealers.
Precondition:
DE-SCALE/ READY is
displayed.
T Press the Rotary Switch.
EMPTY TRAY
T Empty the drip tray and coffee grounds
container and reinsert them.
AGENT IN TANK
T Remove and empty the water tank.
T Completely dissolve the contents of one blis-
ter (three JURA descaling tablets) in a
receptacle holding 500 ml of water. This may
take several minutes.
T Pour the solution into the empty water tank
and reinsert the tank.
PRESS ROTARY
T Place a receptacle under the hot-water
spout.
T Press the Rotary Switch.
DE-SCALING, water flows out of the
hot-water spout repeatedly.
EMPTY TRAY
T Empty the drip tray and coffee grounds
container and reinsert them.
FILL WATER TANK
Loading ...
Loading ...