Operating the appliance
These instructions apply to several appliance variants. It is
possible that individual features are described which do not
apply to your appliance.
Note: Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Control panel
Setting the fan
Note: Always adjust the fan strength to meet current conditions.
If there is a large build-up of steam or fumes, select a high fan
setting.
Switching on
1. Press the 1 button.
The fan starts at level 1.
2. Press the 1, 2, 3 or 4/G button to set another fan level.
The
# button and the button for this fan level light up.
Switching off
Press the
# button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
1. Press and hold the 4/G button while the ventilation system is
switched on.
The
# button lights up and the 4/G button flashes once
every second. Intensive mode is activated.
2. Press and hold the 4/G button or press the # button.
Intensive mode is deactivated.
Note: The run time of the intensive mode is 6 minutes. Once
this time has elapsed, the appliance switches back to the fan
level that was previously set.
Interval ventilation
With interval ventilation, the ventilation system switches on
automatically for 10 minutes every hour. The appliance
switches off after 24 hours.
Note: If the intensive mode or fan run-on are activated, the
interval ventilation is not available.
1. Press the H button.
The
# and H buttons light up. The interval ventilation is
switched on. The fan starts at level 1.
2. Press the H button or the # button.
The interval ventilation is switched off.
Fan run-on time
Note: If the intensive mode is activated, fan run-on is not
available.
1. Select the fan level.
2. Press the y button.
The
# and y buttons light up. The fan continues to run at
this fan level for 15 minutes and then switches off
automatically once this time has elapsed. If the lighting is
switched on, this is also switched off once the run-on time
has elapsed.
3. Press the y button or the # button.
The fan run-on ends before the remaining run-on time has
elapsed.
Lighting
The lighting can be switched on and off independently of the
ventilation system.
Press the
B button.
The
B button lights up.
Setting the brightness
1. Press and hold the B button for 2 seconds.
The brightness is reduced.
2. Press the B button.
The maximum brightness is restored.
Saturation display
When the metal grease filters or the activated charcoal filters
are saturated, the corresponding symbol flashes:
Metal grease filter: H
Metal grease filter and activated charcoal filter: y
When this happens, do not delay cleaning the metal grease
filters or replacing the activated charcoal filters any further; see
section Cleaning and maintenance.
Resetting the saturation displays
1. Switch off the motor and the lighting.
2. Press and hold the H button.
The
# button flashes 3 times. The saturation indicator for the
metal grease filter and for the activated charcoal filter is reset.
Explanation
#
Switches off the fan
1 Switches on fan level 1
2 Switches on fan level 2
3 Switches on fan level 3
4/G
Switches on fan level 4 or intensive mode
H
Switches on interval ventilation
y
Switches on the fan run-on
B
Switches on the lighting