6 Trouble shooting
Problem  Solution
The extractor fan ceases
to function.
The kitchen hood feed cable is not
connected to the network.
There is no electrical current in the
network.
Connect feed cable to the network.
Check that the network has electrical cur-
rent.
Insufficient suction power. Did not set to the right speed and/or
air outlet being blocked.
If the kitchen hood is set up for recircula-
tion, check that the charcoal filter is still
effective.
If the kitchen hood is set up for extraction,
check that the ducting and outlets are not
blocked.
The kitchen is adequately vented to allow
the entry of fresh air.
Hood has switched off du-
ring operation.
The safety cut-out device has been
tripped.
Turn off the hood and then wait for the de-
vice to reset.
If the hood has been installed below the
heights indicated in the installation inst-
ructions, the motor will cut-out frequently
which may damage the hood.
The lamps do not light up. The lamps are burnt out.
The lamps are loose.
Change the lamps.
Tighten the lamps.
Oil leakage. One-way valve and air ventilation
entrance not tightly sealed.
Leakage from the connection of U-
shaped section and cover.
Seal with glue on the one-way valve.
Seal with soap or paint on U-shaped sec-
tion.
Hood shakes during ope-
ration.
Filter is damaged.
The body or motor tightly hung.
Replace the filter as a damaged filter cau-
ses shaking.
Lock the motor tightly or fix the body tight-
ly, respectively.