INSTALLATION
Location of services
All dishwasher services should be located in the cabinet
next to the dishwasher opening.
remove entire plastic
membrane from sink trap
spigot and fit drain hose
to spigot with clamp
the drain hose should not be
extended by more than 2m
otherwise water pump out
problems could occur
min. 400mm
straight section
400mm min.
power outlet
sink
600mm max.
300mm min.
Based on the undercounter height, add the required
number of plastic plinth inserts to the metal plinth�
80mm
1 x insert = 90mm
2 x = 100mm
3 x = 110mm
4 x = 120mm
5 x = 130mm
6 x = 140mm
Use the 2 plastic locking pins to set the position of the
plinth assembly
When installing the adjustable plinth to undercounter
height cabinets 870-920mm, kit #52075772 must be
purchased�
Parts supplied with metal plinth:
1 x 130mm high metal plinth
3 x levelling legs
1 x instruction sheet
Follow the steps above substituting the 130mm metal
plinth and longer levelling legs as per instructions
supplied