Installation
77
EN
Burner and nozzle specifications tables
The nozzles not provided are available at Authorised Service Centres.
Natural gas G20 - 20 mbar AUX SR UR Oven
Rated heating capacity (kW)
1.05 1.8 3.9 2.6
Nozzle diameter (1/100 mm)
72 97 135 120
Pre-chamber (printed on nozzle)
(X) (Z) (S) (H3)
Reduced flow rate (W)
400 500 1600 900
LPG G30/31 - 30/37 mbar AUX SR UR Oven
Rated heating capacity (kW)
1.05 1.8 3.9 2.6
Nozzle diametre (1/100 mm)
50 65 100 76
Pre-chamber (printed on nozzle)
----
Reduced flow rate (W)
400 500 1600 900
Rated flow rate G30 (g/h)
76 131 284 189
Rated flow rate G31 (g/h)
75 129 279 186
Town gas G110 - 8 mbar AUX SR UR Oven
Rated heating capacity (kW)
1.05 1.8 3.9 2.6
Nozzle diametre (1/100 mm)
145 185 340 245
Pre-chamber (printed on nozzle)
(/8) (/2) (/13) -
Reduced flow rate (W)
400 500 1200 900
Town gas G120 - 8 mbar AUX SR UR Oven
Rated heating capacity (kW)
1.05 1.8 3.9 2.6
Nozzle diametre (1/100 mm)
135 175 315 215
Pre-chamber (printed on nozzle)
(/8) (/2) (/13) -
Reduced flow rate (W)
400 500 1400 900