the cabinet. If back of range will not be flush with
the wall (the location of the outlet may not allow the
range to be positioned against the wall), draw a line on
the floor where the back edge of the range will be. Now
install anti-tip brackets (see "Anti-Tip Brackets
Installation", page 10).
If range will not be installed against a cabinet,
move range into final position. Draw a line on the floor
along both sides of the range. If back of range will not
be flush with the wall (the location of the outlet may
not allow the range to be positioned against the wall),
draw a line on the floor where the back edge of the
range will be. Now install anti-tip brackets (see "Anti-Tip
Brackets Installation", page 10).
Gas Supply Installation
-- Manual ShutoffValve
(Connectto112"or3/,/,solidgas
FlareUnion Supply pipe fromthe wallor floor).
Flexible Appliance
Conduit
(Install sufficient length
of flexible conduit
to allow the range to
be pulled completely
out of the cut-out area
for proper servicing.
L
Figure 9
When shipped from the factory, this unit isdesigned to
operate on 4" water column (1.0 kPa) Natural gas
manifold pressure. A convertible pressure regulator (see
figure 2) is connected to the range manifold and MUST
be connected in series with the gas supply line. To
access the regulator, remove the drawer.
For proper operation, the maximum inlet pressure to
the regulator should be no more than 14" of water
column pressure (3.5 kPa).
The inlet pressure to the regulator must be at least 1"
(.25 kPa)greater than the regulator manifold pressure
setting. The regulator is set for 4" water column (1.0
kPa) Natural gas manifold pressure; the inlet pressure
must be at least 5" water column (1.25 kPa) Natural
gas. For LP/Propane gas, the regulator must be set for
10" water column (2.5 kPa) manifold pressure; the inlet
pressure must be at least 11 " water column (2.75 kPa).
The supply line should be equipped with an approved
shutoff valve (see Figure 9). This valve should be located
in the same room as the range and should be in a
location that allows ease of opening and closing. Do not
block access to the shutoff valve. The valve is for turning
on or shutting off gas to the appliance.Open the shutoff
valve in the gas supply line. Wait a few minutes for gas
to move through the gas line.
The gas supply between the shutoff valve and the
regulator may be connected by rigid piping or by A.G.A./
C.G.A.-approved flexible metallic union connected
piping where local codes permit use.
The gas supply piping can be through the side wall of
the right cabinet. The right side cabinet is an ideal
location for the main shutoff valve.
Do not make the connection too tight.
The regulator is die cast. Overtightening may crack the
regulator resulting in a gas leak and possible fire or
explosion.
Assemble the flexible conduit from the gas supply pipe
to the pressure regulator in this order:
1- manual shutoff valve, 2- flare union adapter,
3- flexible conduit, 4- flare union adapter,
5- pressure regulator.
The gas supply line to the shutoff valve should be
1/2" or 3/4" solid pipe.
The user must know the location of the main shutoff
valve and have easy access to it.
When using flexible gas conduit on the range, allow
sufficient slack to pull the range outside the cutout for
cleaning or servicing.
NOTE: Do not allow the flexible conduit to get pinched
between the wall and the range. To visually check,
remove the range drawer.
Use pipe-joint compound made for use with Natural and
LP/Propane gas to seal all gas connections. If flexible
conduit is used, be certain that it is not kinked.
Leak testing of the appliance shall be conducted
according to the manufacturer's instructions.
Check for leaks. After connecting the range to the gas
supply, check the system for leaks with a manometer. If
a manometer is not available, turn on the gas supply and
use a liquid leak detector at all joints and connections to
check for leaks.
Do not use a flame to check for leaks
from gas connections. Checking for leaks with a flame
may result in a fire or explosion.
All openings in the wall or floor where the range isto be
installed must be sealed.