Blade changing procedure
Blade changing procedure
Parts
Blade (a)
Axis (b)
Coupler (i)
Metal washer (e)
Fibre washer (d)
Fibre washer (c)
Fibre washer (f)
Fibre washer (g)
Metal washer (h)
Removing the blade
1. Hold the coupler on the underside of the
jar and using spatula rotate the blade
nut in a clockwise direction.
remove
2. If the coupler is removed (the blade
sticks together with the axis), washers
will come off when you take blade
assembly out of the jar.
W Small parts – be careful not to lose or
forget them.
3. Take the blade assembly out of the jar.
4. Hold the blade assembly with cloth.
Using spatula untighten the blade nut
(turn in a clockwise direction).