Installing of the chimney and fixing of the hood
When the hood is installed in recycling version the chim-
ney has to be positioned with the slots upwards. When
the hood is installed in ducting version it has to be posi-
tioned in the opposite way.
Place the chimney on the frame and fix it to the upper
part of it with the earlier removed screws. When in-
stalling the hood in recycling version make sure that
the slots correspond to the air outlet of the recycling air
outlet piece 15.
Open the lighting unit by slightly pulling the notch.
Remove the unit from the hood by sliding the fixing
pivot.
Remove the filter pushing it towards the back side of
the hood unit and simultaneously pulling downwards.
Remove possible charcoal filters.
In order to fix the hood body to the frame insert the 4
screws 12f in their seats. It is necessary to leave at
least 4-5 mm gap between the screw heads and the
frame plate.
Hook the hood canopy to the frame and turn it to the
left until it reaches the stop, then lock the screws im-
mediately to prevent the hood canopy from falling out
accidentally.
2
1
ELECTRICAL CONNECTION
Connect the Hood to the mains power supply, inserting
a two-pole cut-out switch with contact aperture of at
least 3 mm along the line.
Ensure that the supply cable connector is properly in-
serted into the Suction device socket
Hook up the Commands connector Cmd.
Hook up the Spotlights connector Lux to the socket
provided behind the lighting unit cover.
For the Recirculation Version, fit the Activated Char-
coal Odour Filter.
Replace the filters and the lighting unit.
Cmd
Lux