FIXING THE FRAME
Lift the frame up, making sure that the index over the
frame plate is turned forwards.
Fit the frame slots onto the two screws inserted in the
ceiling as above, and turn until reaching the centre of
the adjustment slot.
Tighten the two screws and fasten the other two screws
provided; before locking the screws completely, it is
possible to adjust the frame by turning it, making sure
that the screws do not come out of their housing in the
adjustment slot.
The Frame must be securely fastened so as to support
both the weight of the Hood and the stress caused by
occasional axial pressure against the fitted Appliance.
After fixing, make sure that the base is stable even
when the Frame is subjected to lateral stress.
If the Ceiling is not strong enough in the area where
the hood is to be fixed, the Installer must strengthen
the area using suitable plates and counterplates an-
chored to resistant structures.
2
1
1
2
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to
the chimney using either a flexible or rigid pipe the
choice of which is left to the installer.
To install a ø 150
To install the dumper 10a ø 150.
Fix the pipe using the pipe clamps 25(not included).
To install a ø 120
To install a ø 120 mm air exhaust connection, insert
the reducer flange 9 on the dumper 10a.
Fix the pipe using the pipe clamps 25(not included).
Remove any activated charcoal filters.
9
ø 120
ø 150
10a