www.napoleongrills.com
5

WARNING!

WARNING!
WARNING!


BUILT IN : The piping up to the gas grill is the
responsibility of the installer and piping should be located as shown in the built-in instrucons. A exible
metal connector is included to simplify the installaon of the unit. Connect this exible metal connector
to the are ng on the end of the manifold. Connect the other end of the connector to the gas piping.
Ensure that the connector does not pass through a wall, oor, ceiling or paron, and is protected from
damage. The installaon must be performed by a licensed gas er in accordance with AS5601 / AG601,
and all connecons must be leak tested before operang the grill.
Do not use a hose to connect the unit except to connect the cylinder regulator to the piping system. It
must be connected with rigid pipe, copper tube or an approved exible metal connector which complies
with with AS5601 / AG601. The gas supply pipe must be suciently sized to supply the kPA specied on
the rang plate, based on the length of the piping run. If installing a side burner, a separate line must be
branched o to the side burner unit and enter the side burner opening at the specied locaon. If the
enclosure is to house a ULPG cylinder, the tank poron of the enclosure must be venlated according
to local codes, and must not have communicaon with the cavity used to enclose the gas grill. A ULPG
cylinder cannot be stored below the gas grill.

This gas grill is cered for outdoor use and should be installed to conform to local codes. Check gas type
and specicaons located on the rang plate located on the back panel of the grill.
Universal Liqueed Petroleum Gas Cylinder Specicaons
WARNING!

If the gas grill is being supplied with Universal Liqueed Petroleum Gas from a portable cylinder, a
regulator specied by the manufacturer must be used. Cart models have been designed for use for use
with an approved 9 kg size Universal Liqueed Petroleum Gas cylinder (not supplied). The Universal
Liqueed Petroleum Gas cylinder must be equipped with a POL tank valve connecon. A dented or rusty
cylinder may be hazardous and should be checked by your Universal Liqueed Petroleum Gas supplier.
Never use a cylinder with a damaged valve. The cylinder supply system must be arranged for vapor
withdrawal and the cylinder shall include a dust cap to protect the cylinder valve. The cylinder shall
incorporate a listed OPD (overll protecon device). Do not store a spare Universal Liqueed Petroleum
Gas cylinder under or near this appliance. Never ll the cylinder beyond 80 percent full.