Loading ...
ReceptacleWiring:
Receptaclewiringshouldbeaminimumof14gauge.Usecopperwireonly.Itisyourresponsibilitytoprovideproper
andadequatereceptaclewiring,installedbyaqualifiedelectrician.
ElectricalRequirements:
A115volt(103.5minimum,126.5maximum),60Hertz,AConly,15amperefusedelectricalsupplyisrequired.Atime
delayfuseortimedelaycircuitbreakerisalsorequired.Aseparatecircuit,servingthisapplianceonly,MUSTbe
provided.
ElectricalConnection:
Electricalgroundingisrequiredonthisappliance.
Recommendedgroundingmethod:
Foryourpersonalsafety,thisappliancemustbegrounded.
Thisairconditionerincludesapowersupplycordwitha
3-pronggroundingplug.Tominimizepossibleelectricalshock
hazard:
cordmustbepluggedintoamatching3-pronggroundingtype
wallreceptacle.
mustbegroundedinaccordancewithNationalElectrical
Code(ANSI/NFPA70-latestversion)andalllocalcodesand
ordinances.
Ifamatching3-pronggroundingtypewallreceptacleisnotavailable,
itistheresponsibilityoftheconsumertohaveaproperlygrounded
3-prongwallreceptacleinstalledbyaqualifiedelectrician.
3-ProngGrounding
TypeWallReceptacle_
3-Prong
Grounding plug
t
Grounding prong
Power Supply Cord
(6 feet long)
FIG. 1
Preparing for Installation
Installation Tips
For wood=frame casement windows:
It may be necessary to construct a frame, using at least
1" thick wood, with a 15-1/2" wide opening.
For brick or cement building construction:
It may be necessary to put a wood stool strip under air
conditioner, for mounting purposes as shown FIG. 2.
wood strip Bottom Rail of
mounted on air conditioner
top of inner sill
inner sl
INDOOR
;r silt
OUTDOOR FIG. 2
Failure to adhere to the following precautions could result in personal injury and product damage.
Because this unit weighs about 60 to 80 pounds, it is recommended that you have someone help you when
installing your new unit, and that you both use proper lifting techniques. Inspect the condition of the window
where unit will be installed. Be sure it will support the weight of the unit.
This appliance must be installed according to all applicable codes and ordinances.
Handle air conditioner with care. AVOID sharp metal fins on front and rear coils.
Make sure your air conditioner does not fall during installation.
Do not use water collected in the unit for drinking purposes. It is not sanitary.
Tools Required
Flat-head screwdriver Carpenter's level Fine tooth saw Knife and scissors
Phillips-head screwdriver ® Tape measure Electric or hand drill Pencil
® DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED IN THESE INSTRUCTIONS.
Loading ...
Loading ...
Loading ...