11
Temperature Sensor Error Codes
Sensor Displayed Code Error Description Action to Take
Single Zone
Temperature
Sensor
Failed temperature sensor in the single zone
compartment. Can lead to
unwanted storage temperatures and/or
spoiled perishable goods.
Call service to have the
temperature sensor replaced and
remove all perishable goods from
compartment to prevent spoilage.
Defrost Sensor
Failed defrost temperature sensor.
Causes unit to not defrost properly and can
create large frost build-up. Can lead to water
damage to the unit and
surrounding oor.
Unplug the power cord
immediately and call service to
have the defrost sensor replaced.
The temperature sensors are monitored continuously.
Any OPEN or SHORTED circuit condition will initiate an
ERROR CODE as listed below:
Temperature Sensor Error Codes
Temperature mode:
The temperature mode is preset from the factory in
Fahrenheit (°F) but you have the option to change it to
Centigrade (°C). To change the mode, press and hold the
"-" keypad, while pressing the "+" keypad, then release the
"-" keypad.
The temperature will now be displayed in Centigrade (°C).
Repeat the procedure to change the temperature mode
back to Fahrenheit (°F).
Control lock:
The control panel can be locked to avoid unintentional
changes. To lock the control, press and hold the "Lock"
keypad until the display reads "Loc" then immediately
release your nger from the keypad. The lock icon will ash
3-times and then continuously illuminate. When the control
panel is locked, only the Lock keypad, System Status OK
indicator , and the Alarm indicator are active. To un-lock
the control panel, repeat this instruction until the display
reads "nLc" then immediately release your nger from the
keypad.
Adjusting the temperature:
To set or check the set-point temperature (with the
control out of sleep mode), press the "-" or "+" keypads.
"SET" will be indicated on the user interface panel and
the current set-point temperature will display and ash.
Subsequent presses of the "-" or "+" keypads will adjust
the temperature colder or warmer respectively. When you
have reached your desired set-point temperature, press
the "On/Off" keypad to accept, or do nothing and the "Set"
mode will time-out in 10-seconds accepting the displayed
temperature as the new set-point.
The available set-point temperature range for your
appliance is 34°F (1.2°C) to 42°F (5.7°C). If you attempt to
adjust the temperature outside of this range you will receive
an audible noti cation.
When initially loading your product with warm contents,
it may take up to 48-hours for the storage compartment
temperature to stabilize.
When making temperature set-point changes, it may take
up to 24-hours for the stored contents to stabilize at your
new set-point temperature.
Factors that affect the storage compartment stabilized
temperature:
Changes to temperature setting.
Room temperature changes.
Temperature of stored contents.
- Loading warm contents.
- Cold content load will delay the change to a warmer
set-point temperature.
- Warm content load will delay the change to a colder
set-point temperature.
Usage, (number and duration of the drawer openings).
Installation of the appliance in direct sunlight or next to
a heat source.
USING YOUR ELECTRONIC CONTROL
NOTE
If the control lock is active (illuminated lock icon) the
control will have to be unlocked before using the
keypad to reset an alarm condition. See page 11