52
ENGLISH
49. IR Operation (Command: t p)
Configures the IR operation settings of the product.
Transmission
[t][p][ ][Set ID][ ][Data][Cr]
Data 00: locks off all of the keys
01: locks on all of the keys except the Power key
02: locks on all of the keys
Acknowledgement
[x][ ][Set ID][ ][OK/NG][Data][x]
* When the monitor is turned off, the power key works
even in the locks on all of the keys (02) mode.
50. Local Key Operation (Command: t o)
Configures the local key operation settings of the product.
Transmission
[t][o][ ][Set ID][ ][Data][Cr]
Data 00: locks off all of the keys
01: locks on all of the keys except the Power key
02: locks on all of the keys
Acknowledgement
[o][ ][Set ID][ ][OK/NG][Data][x]
* When the monitor is turned off, the power key works
even in the locks on all of the keys (02) mode.
51. Status (Command: s v)
Checks the current signal status of the product.
Transmission
[s][v][ ][Set ID][ ][Data][ ][FF][Cr]
Data 02: checks whether there is a signal or not
03: check the PM mode.
05: Checks whether luminance sensors 1 and 2
work properly.
06: Luminance sensor being used:
07: Checks whether the Top, Bottom and Main
temperature sensors are functioning normally.
08: The temperature of each temperature sensor
when the monitor set was last powered off.
09: Fan Speed
10: RGB sensing OK/NG (Check Screen)
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][x]
Data: 02 (when a signal is found)
Data1 00: no signal
01: there is a signal
Data: 03 (when checking the PM mode)
Data1 00: The PM mode is set to Screen On
01: The PM mode is set to Screen Off
02: The PM mode is set to Screen Off Always
03: In Sustain Aspect Ratio mode.
04: Screen Off & Backlight status (Outdoor mode)
Data: 05 (In the case of checking whether the luminance
sensors work properly)
Data1 00: All normal
01: BLU sensor 1 normal, BLU sensor 2 down
02: BLU sensor 1 down, BLU sensor 2 normal
03: All sensors down
Data: 06 (In the case of the luminance sensors being
used)
Data1 00: Luminance sensor 1 is being used
01: Luminance sensor 2 is being used
Data: 07 (In the case of checking whether the Top, Bottom
and Main temperature sensors are functioning
normally)
Data1 00: All temperature sensors are faulty.
01: Top normal, Bottom faulty, Main faulty
02: Top faulty, Bottom normal, Main faulty
03: Top normal, Bottom normal, Main faulty
04: Top faulty, Bottom faulty, Main normal
05: Top normal, Bottom faulty, Main normal
06: Top faulty, Bottom normal, Main normal
07: All temperature sensors are normal
Data: 10 (Check Screen)
Data1 00: Check Screen result NG
07: Check Screen result OK
*In 75XE3C models, the status will be displayed as normal if
both the Top (Panel) and Top (PSU) are normal.
* Sets to NG when Check Screen is set to Off or not supported.
Data: 08 (In the case of checking the temperature of each
temperature sensor when the monitor set was
last powered off)
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][Data2]
[Data3][x]
Data1: The temperature of the Top sensor when the
monitor set was last powered off.
Data2: The temperature of the Bottom sensor when the
monitor set was last powered off.
Data3: The temperature of the Main sensor when the
monitor set was last powered off.
Data: 09 (In the case of Fan Speed)
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][Data2][x]
Data1: 00-ff: The upper 1-byte of the fan speed
Data2: 00-ff: The lower 1-byte of the fan speed
Fan speed: 0 to 2008 in hexadecimal and 0 to 8200 in
decimal
** This may not be supported on some models.
Loading ...
Loading ...
Loading ...