Loading ...
Loading ...
Loading ...
Installation
85
EN
5.2 Gas connection
General information
Connection to the gas mains can be made
using a continuous wall steel hose in
compliance with the guidelines established
by the standards in force.
For supplying it with other types of gas, see
chapter “ Adaptation to different types of
gas”. The gas inlet connection is threaded
½” external gas (ISO 228-1).
Connection with a rubber hose
Verify that all following conditions are met:
• The hose is attached to the hose
connector with safety clamps
• No part of the hose is in contact with hot
walls (max. 50 °C)
• The hose is not under traction or tension
and has no kinks or twists
• The hose is not in contact with sharp
objects or sharp corners
• If the hose is not perfectly airtight and
leaks gas, do not try to repair it; replace
it with a new hose
• verify that the hose is not past its expiry
date (serigraphed on the hose itself).
Make the connection to the gas mains
using a rubber hose whose specifications
comply with current standards (verify that
the reference standard is stamped on the
hose).
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and
15 Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• Installation using a hose must be carried
out so that the length of the hose does
not exceed 2 metres when fully
extended for steel hoses and 1.5 metres
for rubber hoses.
• The hoses should not come into contact
with moving parts and should not be
crushed in any way.
Loading ...
Loading ...
Loading ...