User manual for Portable Air Conditioner
The window installation kt allows you to install the air conditioner in most vertical-sliding windows 18" horizontal sliding windows from 18" to 50” high.



For an 18" window opening, use the window vent panel by itself.
Fig."a"

For window openings from 19" to 26", use the window vent panel ( Panel A) and a extension panel ( Panel B)
Fig."b"

For window openings from 27" to 34", use the window vent panel ( Panel A) and a extension panel ( Panel C).
Fig."c"

For window openings from 35" to 50", use the window vent panel and two extension panel ( Panel C and Panel D).
Fig."d"
Install Exhaust Hose and Adapter
1. Roll the aie conltioner to selected location. see “Location Requirements.”
2. Attach the couping tothe flexible exhaust hose. Turn counter cockwise unt securely locked into place

3. Attach the window exhaust adapter tothe flexible exhaust hose. Turn counter-clockwise untl securely locked into place.

A. Flexible exhaust hose
B. Window exhaust adapter
4. Insertthe coupling into the stot onthe back ofthe air conditioner.
5. Slide down to lock the hose into place.

A. Flexible exhaust hose
Note: Product must be used with included Duct Window installation kit for effective cooling.

A. Outer slider section
B. Window exhaust adapter
NOTE:The window installation kit can be used with vertical sliding windows between 18" and 60" wide.

Cut the foam seal L(adhesive type) & M (adhesive type-shorter)to the proper length. and attcah it to the window sash and frame.

Insert the vent panel assembly. including extension panels. if needed. into the window opening. Extend the extension panels. if used.

Cut the foam seal A(Non-adhesive type) to the window width. Stuff the foam seal A between the glass and the window to prevent air and insects from getting into the room.

Install the Window-lock bracket with a type F screw as shown if you need.
NOTE:The window installation kt can be used with vertical sliding windows between 18" and 50" wide.

Cut the foam seal L(adhesive type) & M {adhesive type-shorter)to the proper ength. nd attcah it to the window sash and frame.

Insert the vent panel assembly. including extension panels. if needed. into the window opening. Extend the extension panels, if used.

Cut the foam seal A(Non-adhesive type) to the window width. Stuff the foam seal A between the glass and the window to prevent air and insects from getting into the room.

Install the Window-lock bracket with a type F screw a3 shown if you need.
Operating your portable air conditioner property helps you to obiain the best possible results.
This section explains proper air conciioner operation.
IMPORTANT:
If button is pressed during this time. the compressor will not restart for another 3 to 5 minutes.
NOTE: In the event of a power failure. your alr conditioner wil. operate at the previous settings when the power is restored.
Control panel

Note: The symbols may be different from these models, but the functions are similar.
Front display

Note: The figures in this manual are besed on the external view of a standard model. They may differ from that of the air conditioner you have selected.
Power On or Off

NOTE:
Mode
1. Press and release MODE until you see the symbol for the desired setting.
Operating modes:

2. Choose Cooling, Dry, Fan or Heating.
Cooling Cools the room. Press FAN to select High, Mid or Low. Press the Plus or Minus button to adjust the temperature.

Dry-Dries the room. The air conditioner automatically selects the temperature. The fan runs on Low speed only. Dehumidification ranges between 2 to 3 pints per hour, by model.
NOTE: Dry mode should not be used to cool the room.

Fan Only mode. Press FAN to select High, Mid or Low.

Heating-heats the room. Press FAN to select high, Mid or Low. Press the PLUS or MINUS button to adjust the temperature.
NOTE: Heating is NOT available for cooling. To cool,that mode must be selected.

Fan Speed
1. Press and release FAN to choose the desired fan speed.

2. Choose High, Mid or Low. Auto-automatically controls the fan speed depending on the current room temperature and temperature control setting.
High-for maximum fan speed

Mid-for normal fan speed

Low-for minimum fan speed

Temperature
Press the PLUS button to raise the temperature. Press the PLUS button once to increase the set temperature by 1°F (1°C).

Press the MINUS button to lower the temperature. Press the MINUS button once to decrease the set temperature by 1°F (1°C).

NOTE: In the Cooling mode, the temperature can be set between 61°F and 86°F (16°C and 30°C).
In Fan Only mode, the temperature cannot be set.
To change the temperature display between °C and °F press both the Plus and Minus Adjust buttons at the same time.

ION (Optional)
Press the ION button to start or stop the Plasma Generator.

When the ION indicator light of the appliance flashes, the Plasma Generator will turn on.
1. Remove the battery cover along the arrowed direction.

2. Insert new batteries making sure that the (+) and (-) of battery are matched correctly.
3. Re-attach the cover by sliding it back into position.

NOTE:
The clip on the back of the unit can be used to store the remote control.

To operate the room air conditioner, aim the remote controller to the signal receptor. The remote control will operate the air conditioner at a distance of up to 23' (7m) when pointing at signal receptor of the air conditioner.

Note: Remote control may differ in appearance.

Button and Function

NOTE: Your remote control could change the displaying between fahrenheit and degree centigrade by pressing: MODE and DOWN buttons at the same time.
Indication symbols
Indication symbols on LCD:


SMART Mode
Press the SMART button, regardless If the unit is on or off, to set temperature and fan speed automatically based on the actual room temperature.

Operation mode and temperature are determined by indoor temperature.
With Heater/Heat pump models

Cooling only models

NOTE Temperature, airflow and direction are controlled automatically in smart mode. However, a decrease or rise of up to 4°F (2°C) can be set with the remote controller if you still feel uncomfortable.

SUPER
SUPER button is used to start or stop fast cooling or heating.
1. Press SUPER button. The air conditioner automatically sets the fan speed to High and the temperature to 61°F (16°C). Fast heating operates at auto fan speed, changing the set temperature automatically to 86°F (30°C)

2. To turn off Super control, press any button on the remote control or control panel except Timer On, Timer Off, Clock, Dimmer, Ifeel and Swing.
NOTE:

Sleep mode
SLEEP mode can only be sat in Cooling, Heating or Drying When in sleep mode the unit will utilize lower, quieter fan speeds and automatic temperature adjustments offering 8 hours of optimal sleeping conditions before shutting off.

NOTE:
1. Press MODE to select Cooling, Heating or Dry. NOTE: Sleep control cannot be selected in Fan mode.
2. Press the UP or DOWN button to set the temperature,
3. Press SLEEP, After 5 seconds, the lights on the control panel display will dim.
NOTE. The temperature and airflow direction may be adjusted during Sleep control. The fan speed is automatically set to Low speed, After 5 seconds, the lights on the control panel display will dim again.
4.To turn off Sleep control, press SLEEP, MODE, ON/OFF,FAN, SUPER or wait 8 hours for Sleep control to turn off automatically.
NOTE: The air conditioner will return to previous settings after Sleep mode is turned off.
I FEEL
The temperature sensor built into the remote control can sense its surrounding temperature, and transmit the signal back to the unit. The temperature is adjusted to provide maximum comfort.

NOTE:

DIMMER
Press the DIMMER button to turn off the control panel display.

NOTE: When in DIMMER mode, new control inputs will return display to normal.
Clock function
1. You can set the real time by pressing the CLOCK button.

2. Use the Up and Down buttons to set the correct time.

3. Press the CLOCK button again and the real time is set.
TIMER ON/OFF
Set the timer with the TIMER ON/OFF buttons.
NOTE: The CLOCK must be set before using the TIMER function.
Using the TIMER
The TIMER ON button can be used to turn on the unit automatically at a preset time.
1. Press TIMER ON, then "On 12:00" flashes on the LCD.

2. Press the UP or DOWN button to set the time of dayto turn on the appliance.

3. When the desired time is displayed on the LCD, press the TIMER ON button to confirm it. A "Beep" will be heard, and "ON" stops flashing. The TIMER indicator on the appliance lights up,indicating the TIMER is set.
4. After the preset time is displayed for 5 seconds, the clock will display on the LCD of remote controller instead of the TIMER setting.
To cancel TIMER On
Press the TIMER ON button again, when a "beep" is heard and the indicator disappears, the TIMER ON mode has been canceled.
TIMER OFF is set exactly the same way as TIMER ON. However, TIMER OFF is set when the unit is running, and sets the time at which the unit will turn off.

SWING
Press SWING once to change the vertical airflow direction. Press again to hold the louver in a desired position.

NOTE:
Normal Sounds
When your air conditioner is operating normally, you may hear sounds such as:

A.Primary drain cover B.Primary drain plug
1. Unplug the air conditioner or disconnect power.
2. Move the air conditioner to a drain location or outside. NOTE: To avoid leaking water from the unit, move the air conditioner slowly and keep it level.
3. Remove the primary drain cover and plug.
4. Drain water completely through the drain hole. NOTE: If the air conditioner will be stored after use, see "Storing After Use".
5. Reinstall the drain plug to the primary drain hole.
6. Reinstall the primary drain cover to the drain hole.
7. Reposition the air conditioner.
8. Plug in the air conditioner or reconnect power.

A.Primary drain port
B.Drain hose
C.Primary drain hole
WARNING: Please connect the drain hose on heating mode, or the unit will stop running after the water reaches warning level.
1.Uncover the primary drain port.
2.Attach the drain hose to the primary drain hose. Make sure the connector is no water leak.
3. Place the other end of drain hose into a outfall. Check to see that the hose lies flat and is in the drain. Make sure the hose end that gose to the drain is on a lower level than the hose end that connects to the unit. The hose should not be kinked or pinched.
1. Press ON/OFF to turn off the air conditioner.
2. Unplug the air conditioner or disconnect power.
3. Remove the air filter and clean separately. See "cleaning the Air Filter".
4. Wipe the outside of the air conditioner with a soft, damp cloth.
5. Plug in the air conditioner or reconnect power.
6 Press ON/OFF to start the air conditioner.

A.Evaporator air intake fliter panel door
B.Condenser air intake fliter panel door
1. Press ON/OFF to turn off the air conditioner.
2. Open the filter panel door on the back of the air conditioner and remove.
3. Remove the tapping screw from the condenser air intake filter panel door and remove.
4. Use a vacuum cleaner to clean the filter. If the filter is very dirty, wash the filter in warm water with a mild detergent. NOTE: Do not wash the filter in the dishwasher or use any chemical cleaners.
5. Air dry the filter completely before replacing to ensure maximum efficiency.
6. Reattach the air filter to the filter panel door.
7. Reinstall the filter panel door and tapping screw.
8 Press ON/OFF to start the air conditioner.
1. Drain the water completely. See "draining the Air Conditioner ".
2. Run the air conditioner set to Fan Only for approximately 12 hours to dry the air conditioner.
3. Unplug the air conditioner.
4. Remove the flexible exhaust hose and store with the air conditioner in a clean, dry area. See" installation Instructions "
5. Remove the window kit and store with the air conditioner in a clean, dry area. See " Installation Instructions".
6. Remove the filter and clean. See Cleaning the Air Filter.
7. Clean the outside of the air conditioner. See "Cleaning the Outside".
8. Reinstall the filter.
9. Remove the batteries and store the remote control with the air conditioner in a clean, dry area.
The power supply cord is unplugged.
Time-delay fuse or circuit breaker of the wrong capacity is being used.
The power supply cord has tripped (Reset button has popped out).
A household fuse has blown, or a circuit breaker has tripped.
The On/Off button has not been pressed.
The local power has failed.
Too many appliances are being used on the same circuit.
You are trying to restart the air conditioner too soon after turning off air conditioner.
Disturbances in your electrical current can trip (Reset button will pop out) the power supply cord.
Electrical overloading, overheating, cord pinching or aging can trip (Reset button will pop out) the power supply cord.
NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.
Is there a door or window open?
The current air conditioner replaced an older model.
The air conditioner is in a heavily occupied room, or heat producing appliances are in use in the room.
Set temperature is close to room temperature.
If the unit displays error code E5, the water container is full. Drain the water, see "Draining the air conditioner". After draining, the unit can be operated again.
The filter is dirty or obstructed by debris.
Air outlet is blocked.
Set temperature is too high.
The air conditioner is not properly sized for your room.
The filter is dirty or obstructed by debris.
There is excessive heat or moisture, open container cooking, showers, etc. in the room.
The louvers are blocked.