Loading ...
Loading ...
Loading ...
9
6. Using 2 or more people, lift the range hood assembly under
the structure.
7. Attach the range hood assembly to lower vertical supports
with 2 leveling screws and 2 nuts.
8. Install the 4 vertical supports with 16 - 4.2 x 8 mm screws
Make sure all screws are securely tightened.
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
3. Use caulk to seal all openings.
Non-Vented (Recirculating) Installation
1. Attach the air deector to the upper horizontal support using
4 mounting screws.
2. Measure the length of 6" (15.2 cm) duct needed to connect
the transition to the deector.
NOTE: Vent should t up inside the deector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deector.
NOTE: To make vent installation easier, temporarily remove
the deector from the chimney support bracket, and then
replace after vent section is in place.
4. Seal all connections with vent clamps.
B
A. Lower vertical supports
B. Range hood assembly
A
B
C
D
A. 2 - leveling screws
B. Lower vertical support
C. Place leveling screws through the structure
D. Nut
B
A. 4 - Lower vertical supports
B. 16 - 4.2 x 8 mm screws
B
B
A
A. Deector
B. Mounting screws
Loading ...
Loading ...
Loading ...