Whirlpool KVIB606DBS cooking

User Manual - Page 5

For KVIB606DBS.

PDF File Manual, 36 pages, Download pdf file

Loading ...
Loading ...
Loading ...
5
Product Dimensions
Installation Dimensions
IMPORTANT:
Minimum distance “C”: 24" (61.0 cm) from electric cooking
surface.
Minimum distance “C”: 27" (68.6 cm) from gas cooking
surface.
Suggested maximum distance “C”: 36" (91.4 cm)
The chimneys can be adjusted for different ceiling heights. See
the following chart.
Vented Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 9" (2.36 m) 9' 10" (3.0 m)
Gas cooking
surface
8' (2.44 m) 9' 10" (3.0 m)
Non-Vented (Recirculating) Installations
Min. ceiling height Max. ceiling height
Electric cooking
surface
7' 9" (2.36 m) 10' 4" (3.15 m)
Gas cooking
surface
8' (2.44 m) 10' 4" (3.15 m)
*NOTE: The range hood chimneys are adjustable and designed
to meet varying ceiling or soft heights, depending on the
distance “C” between the bottom of the range hood and the
cooking surface. For higher ceilings, a Chimney Extension Kit is
available from your dealer or an authorized parts distributor. The
chimney extension replaces the upper chimney shipped with the
range hood. To order, see the “Assistance or Service” section.
Venting Requirements
Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other
enclosed area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended. Do
not use plastic or metal foil vent.
The vent system must have a damper. If the roof or wall
cap has a damper, do not use the damper supplied with the
range hood.
For the Most Efcient and Quiet Operation:
Use a straight run or as few elbows as possible.
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight
vent between the elbows, if more than 1 elbow is used.
Do not install 2 elbows together.
Use vent clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold airow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system. The damper should be on the cold air side of the
thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of air
movement. The specied CFM varies from locale to locale.
Consult your HVAC professional for specic requirements in your
area.
27" (68.6 cm)
36" (91.2 cm)
42" (106.4 cm)
*Vented installations only
**Non-vented (recirculating) installations only
B
C A
D
A. Ceiling height
B. Hood height from ceiling to bottom of the
range hood: A - C - D = B
C. 24" (61.0 cm) minimum to 36" (91.4 cm)
maximum suggested hood height
D. Countertop height
Loading ...
Loading ...
Loading ...