Lowes.com/harborbreeze
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan does not
move.
1. The reverse switch is not
engaged.
2. The wall switch is turned off.
3. The power is off or the fuse
(breaker) is blown.
4. There is a faulty wire
connection.
1. Firmly push the reverse switch to
either the left or right.
2. Make sure the wall switch is turned
on.
3. Turn the power on or check the fuse
(breaker).
4. Turn the power off and check all
connections at the ceiling outlet box.
The fan is noisy.
1. The blades are loose.
2. There is a cracked blade.
3. The wall control is not
compatible with the fan.
4. The break-in period has not
surpassed.
5. The outlet box is not secure.
6. The mounting bracket is not
secure.
1. Check and tighten all screws that
hold the fan blades to the blade
arms and the motor.
2. Replace the cracked blade.
3. Do not use a full range dimmer
switch to control the fan speed.
4. Run the fan continuously for 24 - 48
hours on medium or high speed for
a “break in” period.
5. Ensure the outlet box is secured to
the building structure.
6. Ensure the mounting bracket is
secured to the outlet box and that
the screws are tight.
There is excessive
wobbling.
1. The blades and/or blade are
loose.
2. The blades are unbalanced.
3. The fan mounting is not
secure.
4. The fan is too close to the
vaulted ceiling.
5. The set screw on the motor
housing yoke is loose.
1. Check and tighten all screws that
hold the fan blades to the blade
arms and the blade arms to the
motor.
2. Switch one blade with a blade
from the opposite side. Or balance
the fan using a balancing kit (not
supplied).
3. Turn off the power. Loosen the
canopy and verify that the mounting
bracket is secure to the electrical
outlet box. The bracket must be
ushwithoutmovementagainstthe
outlet box.
4. Use a longer downrod or move the
fan to another location.
5. Lift up the yoke cover and tighten
the set screw to the yoke until
secure.