Loading ...
Loading ...
Loading ...
1
Enter Special Features mode. See To Enter Special
Features section above.
2
Remove all articles from the washer basket.
3
Press the Extra Rinse button.
The My Cycle Settings and lights will go out. The Start
button light will blink. The corresponding Tank Levels
lights will show the current tank level.
4
Press the Start button.
The tank will dispense for the minutes shown in the
display to empty the selected tank. The Tank Levels
lights will cycle up and down during the flush operation.
Once finished, the Tank Levels should indicate an
empty tank with lowest level light remaining on and
the Start button light will flash. You can (repeatedly)
refill the tank with water and press the Start button to
rinse out the tank as needed.
NOTE: If you suspect that the dispenser is plugged, add
lemon juice to make the water slightly acidic.
5
Press the Power button to exit (when the tank is
empty).
This function will automatically exit if neither button is
pressed for 2 hours.
NOTE: Bulk tank flush is recommended if you:
1)
Change detergent or softener brands
2)
Accidently add softener to the detergent tank or
vice versa
3)
Put powdered detergent in the detergent tank
4)
Put non-concentrated fabric softener in the
softener tank
10
About special features.
To Enter Special Features
To Enter the Special Features mode for a specific tank:
1
Press the Power button.
2
Simultaneously press and hold either the
Detergent Tank On and Detergent Cup Amount buttons
for 3 seconds
or
Softener Tank On and Softener Cup Amount buttons for
3 seconds
The My Cycle Settings and Extra Rinse lights will flash to
indicate you are in the Special Features Mode.
OR
Option 1: Set Concentration Settings
NOTE: During initial installation, or if the household
water pressure dramatically changes, the bulk
dispenser will change to accommodate your homes’
unique water pressure. Wait a few wash cycles before
changing concentrations.
The factory default concentration setting number
for normal level of detergent (2 LED’s on) is 15 (1.5 oz
(or 44 ml)) and 10 (1.0 oz (or 30 ml)) for softener. To
allow maximum user flexibility either of these can be
changed to between 0.5 and 10 ounces.
1
To view or change the current concentration
levels, enter Special Features mode. See above.
2
Press the My Cycle Settings button.
Now only the My Cycle Settings light and all the
Cup Amount lights will be on and the current
concentration number will be displayed.
3
Turn the cycle knob to increase or decrease the
concentration number in the display for the
Medium level. The High and Low concentrations
are scaled automatically from the concentration
setting number of this adjustable number. See
table below for allowable ranges, increments, and
number to ounces conversion.
4
Press the Cup Amount button to save the newly
selected number and exit this function. The display
will reflect whatever cycle the cycle knob is on.
To exit without changing the setting, press the Power
button. This function will automatically exit (without
saving) if neither button is pressed within 1 minute.
Option 2: SmartDispense
TM
Tank Cleaning
The following table shows the approximate amount dispensed (oz) at each Cup Amount setting (1, 2 or 3) for each
Concentration Setting:
Number of
Loads*
* For a 100 oz (2957 ml) bottle for normal ( ) setting.
NOTE: Special Features mode will automatically exit if
no further action is taken within 1 minute.
Concentration
Setting
200 100 67 50 40 33 29 25 22 20 18 17 15 14 13 13 12 11 11 10
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
0.6 1.3 1.9 2.5 3.1 3.8 4.4 5.0 5.6 6.3 6.9 7.5 8.1 8.8 9.4 10.0 10.6 11.3 11.9 12.5
0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0
0.4 0.8 1.1 1.5 1.9 2.3 2.6 3.0 3.4 3.8 4.1 4.5 4.9 5.3 5.6 6.0 6.4 6.8 7.1 7.5
Loading ...
Loading ...
Loading ...