Loading ...
Loading ...
Loading ...
LIGHT - Switch C. When light switch is on "AUT" position the light will be turned on and off automatically by opening and
closing the visor. When set to "0" position, the light will remain off, regardless of position of visor.
On "MAN" position the light will be switched on regardless of position of visor.
CONTROLS shown in Fig. 10:
Button A: turns the lights on/off; every 30 hours of operation the corresponding pilot lamp (S) illuminates to indicate that
the grease filters must be cleaned; every 120 hours of operation the corresponding pilot lamp (S) flashes to indicate that
the grease filters must be cleaned and the charcoal filter replaced. To restart the hour counter (RESET), hold the button
A pressed down for about 1” (while the pilot lamp S is on). Button B: drives the motor in first speed (the corresponding
pilot lamp comes on); when holding it down for about 1”, the motor cuts out. Button C: drives the motor in second speed
(the corresponding pilot lamp comes on). Button D: drives the motor in third speed (the corresponding pilot lamp comes
on). Button E: drives the motor in fourth speed (the corresponding pilot lamp comes on).
Provision has been made to
delay switching off of the hood to allow completion of ambient air purification. Starting from
2
nd
speed, when pressing the current operating speed button (pilot lamp on), switching off will be delayed for 5’. During
this period the pilot lamp flashes.
FILTER ALARM:
After 30h of operation, the Light Button LED (Fig. 10S) comes ON; It indicates that the anti-grease filters need to be
cleaned. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by
pressing the key C during display of the filter alarm.
CONTROLS shown in Fig. 11:
A) Turns the LIGHTS off
B) Turns the LIGHTS on.
C) Decreases speed down to minimum speed. If pressed for 2" the motor is turned off.
D) Activates the motor (calling the last speed used) and increases the speed until reaching maximum..
E) FILTER ALARM/TIMER RESET: when pressing the key during display of the filter alarm (motor off) it resets the hour
counter. When pressing the key when the motor is running, the TIMER is activated and the hood will automatically be switched
off after 5 minutes.
L1) The 4 green LEDs indicate the running speed.
L2) When the LED is red (motor off) it indicates the FILTER ALARM. When the LED is green (flashing) it indicates that
the TIMER has been activated with the key E.
FILTER ALARM:
After 30h of operation, the LED L2 turns RED. It indicates that the grease filters need to be cleaned.
After 120h of operation, the LED L2 turns RED and flashes; It indicates that the grease filters need to be cleaned and
the charcoal filters replaced.
After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing the
key E during display of the filter alarm.
CONTROLS shown in Fig. 12:
P1) OFF/- Lights: Decreases light intensity down to minimum intensity. If pressed for 2 seconds, the lights are switched
off.
P2) ON/+ Lights: Switches on the lights using the last brightness level set (prior to the last time the lights were switched
off).Increases light intensity up to maximum intensity.
P3) OFF/- Engine: Decreases speed down to minimum speed. If pressed for 2 seconds, the engine is switched off. If
pressed for 2 seconds when FILTER ALARM is active, HOUR metering is reset.
P4) ON/+ Engine: Switches on the engine using the speed set (prior to the last time the engine was switched off).Increases
the speed of the engine up to maximum speed (NON INTENSIVE). If pressed for 2 seconds, the 5-minute Timer is activated
and HIGHLIGHTED by flashing speed indication LEDs. If pressed for 2 seconds when the Timer is active, it is ELIMINATED.
P5) INT: Only functions with ENGINE ON. If pressed once, it activates the FIRST intensive speed; if pressed for a second
times, the SECOND intensive is activated; if pressed for a THIRD time, the speed set prior to the intensive (that is one
of the first 4) is set again.
L1) The 4 green LEDs indicate the running speed.
L2) 2-colour LED: GREEN indicates the First Intensive Speed RED indicates the Second Intensive Speed.
FILTER ALARM:
After 30h of operation, the first 2 LEDs (L1) flash; this indicates that the grease filters need to be cleaned.
After 120h of operation, the last 2 LEDs (L1) flash; This indicates that the grease filters need to be cleaned and the
charcoal filters replaced.
After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing
the key P3 during display of the filter alarm.
Charcoal filter replacement (for filter version hoods): Remove the filters by rotating them and fit them back on by
rotating them in the opposite direction / 13). If the model you have purchased has the controls shown in Figure 9
and in Figure 10, replace the charcoal filters on average every 6 months depending on use.
Loading ...
Loading ...
Loading ...