It is recommended after every use or when required that
following items are cleaned.
NOZZLE
When the nozzle is clogged, it will cause the pump to build
pressure and may cause unit to surge, you can clean the nozzle
inserting needle into the tip to rid of the deposits.
For the adjustable nozzle, you can also lubricate the nozzle
collar (high pressure to low pressure ) by using non-water
soluble grease regularly.
INLET FILTER
The inlet filter may become blocked.
To check and clean:
1. Turn unit OFF and disconnect from mains power.
2. Turn water OFF.
3. Bleed off excess water and disconnect from mains water.
4. Unscrew and remove hose connector.
5. Remove white filter and check and clean.
6. Once clean replace white filter and re-fit the
hose connector.
7. Turn Water on and bleed pressure washer.
8. Turn pressure washer on and resume cleaning.
CLEANING
NEVER use this pressure cleaner to clean itself. Damage caused
by cleaning the pressure washer with its own gun will not be
covered under warranty. Ensure pressure washer is cool before
cleaning, about 1 hour after use.
Wipe down all surfaces with a soft clean cloth.
Rinse all nozzles, detergent bottle in a bucket of clean water.
Allow to dry before storing.
STORAGE
NOTE: When storing the pressure washer, parts, and
accessories always store in a secure area with a temperature
above 0° C.
LONG-TERM STORAGE
FOLLOW ALL OF THE NORMAL SHUT-DOWN PROCEDURES
HOWEVER ADD THESE FOLLOWING STEPS….
After disconnecting the water supply, and before
disconnecting the high-pressure hose, turn the pressure
cleaner on for 2-3 seconds, until any remaining water in the
pump exits. TURN UNIT OFF IMMEDIATELY.
CONTINUED USE OF THE PRESSURE CLEANER WITHOUT
WATER SUPPLY ATTACHED WILL CAUSE SEVERE DAMAGE TO
THE UNIT!