Loading ...
Loading ...
Loading ...
10
CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and
a light switch to control cooking area lights.
Models with mechanical control panel
IHVP 6.6 LM K
T1. ON/OFF light switch
T2. Speed 1/OFF switch
T3. 2-speed selection
T4. 3-speed selection
Models with Soft Button panel + LCD Display
IHVP 6.4 AL K
1. OFF / Extraction speed (power) decrease button
2. ON / Extraction speed (power) increase button
Note: The intensive extraction speed (power) is timed and lasts for 5
minutes (indicator c flashes); the hood then reverts to extraction speed
(power) 2.
3. ON/OFF Timer button: delays the deactivation of the selected extraction
speed (power) by 5 minutes.
Note: the button is also used for the "Filter saturation signal reset" function
4. Light ON/OFF button
5. Display, shows:
a. Extraction speed (power): the indicator rotates according to the
selected extraction speed (power).
Safety operation: the indicator flashes.
b. Grease filter saturation: comes on when filter maintenance is
required.
c. Timer
d. Active carbon filter saturation: comes on when filter maintenance is
required.
Note: this function is normally disabled and should only be activated if
the hood is used as a filter version (with carbon filter fitted).
To do so, proceed as follows:
- switch off the hood
- press and hold buttons 1 and 3 at the same time, until the indicator
stops flashing (indicator disabled) and is lit steadily (indicator enabled).
- release the buttons.
To deactivate it, repeat the procedure: the indicator will no longer be lit
steadily (indicator enabled) and will flash instead (indicator disabled).).
e. Lighting
Safety operation
The hood has a sensor which, in the event of a sudden increase in temperature,
activates the appliance until the temperature drops significantly.
Filter saturation signal reset
After carrying out filter maintenance, press and hold button 3 until indicator.
Loading ...
Loading ...
Loading ...