Compressor operates for
a long time and no frost
on the surface of the
evaporator
Refrigeration system is at fault
(leakage or blocked)
Call for service
There is frost or ice on
the walls of the inner
cabinet and internal
temperature is too low,
the compressor never
stops running.
Thermostat does not work
Call for service
The temperature setting of the
thermostat is too low.
Adjust to a higher
temperature
The internal temperature
is too high, and the
compressor never stops
operating.
Bad heat dissipation and ventilation
of condenser
Improve ventilation
Too many warm items were put in at
one time
Remove some goods so
air can circulate
Door is being opened too frequently
during initial cool down
Permit the unit to cool
down adequately, prevent
product access during this
phase
Too noisy
The unit is not level
Adjust the adjustable legs
The fastener of the unit is loose
Tighten the loose fastener
Pipe near the compressor are
touching
Carefully separate the
touching pipes
The side of unit is hot
The condenser in the side wall gives
out heat as part of normal operation
Nothing to worry about.
Sometimes a light sound
of water flowing will be
heard
Refrigerant flowing inside the pipe.
Nothing to worry about.
The display shows “So”
and compressor does not
run
The temperature sensor is open
circuit
Call for service
The display shows “SC”
and compressor does not
run
The temperature sensor is short
circuited.
Call for service
The display shows “HH”
and compressor does not
run
The ambient temperature is above
40°C/104
Stop using immediately
The display shows “LL”
and compressor does not
run
The ambient temperature is below -
40°C/-40°F.
Stop using immediately
If you continue to experience issues, contact Accucold’s
technical support department at 718-893-3900.