8 normal operation Kelvinator gas continuous flow hot water system
Normal operation
Note: The temperature setting can only be changed by the
controller if the priority lamp is lit. If multiple remote controllers
are installed, you can transfer the priority by pressing the
“Priority” button on the relevant controller but only if there
is no water flowing through the water heater (close all open
hot taps or fixtures). Each controller can individually store a
temperature setting but when the priority setting is transferred
to the MAIN controller and the previous setting was set to
above 50°C, it will become 50°C. When the priority setting is
transferred to a SHOWER or ENSUITE controller, if the previous
setting was 42°C or above, for safety reasons it will become
42°C. If a tempering valve has been installed, the hot water
flowing through the tempering valve will not be able to go
above the setting set on the tempering valve e.g. 50°C.
warning
Water temperatures above 50°C can cause severe burns,
scalding or death. Children and disabled or elderly
persons are particularly at risk of being injured. Feel the
water temperature before bathing or showering and do
not leave children or disabled persons unsupervised.
A tempering valve must be installed on the hot water
system in order to temper any water supplying fixtures
primarily used for the purposes of personal hygiene as
per the Australian standards.
4. Open a hot water tap or xture.
5. Ensure the “Burner On” display indicator is lit.
6. Adjust the water temperature by using the remote
controller and mixing cold water as required.
Note: If the "Burner On" display indicator is lit, for safety
reasons the temperature on the MAIN controller will not
be able to be increased above 50°C. If using a SHOWER or
ENSUITE controller, for safety reasons the temperature will not
be able to be increased above 42°C. If these temperatures are
desired, first close all hot water taps or fixtures then increase
the temperatures as desired.
7. Close the hot water tap or xture.
8. Ensure the “Burner On” display indicator is off.
priority lamp
priority button ON/OFF button
burner on
lamp
display set temperature
Please note the following flow rates to properly operate the
hot water system:
Flow rate to activate the water heater:
3.0 litres per minute
Flow rate to keep the water heater running:
2.5 litres per minute
Without remote controllers installed
1. Open a hot water tap.
2. Mix cold water with the hot to get the correct
temperature water.
3. Close the hot water and cold water taps.
With remote controller(s) installed
1. Press the “On/Off” button to activate the display on the
controller.
2. Press the “Priority” button and ensure the priority lamp is
lit on the remote controller being used. Once the priority
lamp is lit confirm that the set temperature is displayed
on the controller(s).
3. Set your desired temperature by pressing the "+" and "-"
buttons. If you are using the MAIN controller the output
temperature can be adjusted within the range of 37°C to
60°C. If you are using a SHOWER or ENSUITE controller
the output temperature can be adjusted within the range
of 37°C to 50°C.
Note: If you have an "A" series main remote controller installed
it will have max temperature setting option of 55C.