For INF26EN60. Also, The document are for others Continuus models: INFINITY 32 REU-VR3237WG INFINITY 26 REU-VR2626WG INFINITY 26 PLUS REU-VRM2630WD INFINITY 26I REU-VR2632FFUG INFINITY 20 REU-VR2024WG INFINITY 16, REU-VR1620WG, INFINITY, ENVIRO 32, REU-KM3237WD, ENVIRO 26, REU-KM2635WD, V1500, REU-VR2426WB, V1200, REU-VR1620WB, HD250E, REU-VRM3237WC, HD200E, REU-VRM2632WC, HD200I, REU-VRM2632FFUC

Loading ...
Loading ...
Loading ...
Rinnai Australia 5 Operation Manual
OPERATION WITHOUT CONTROLLERS
Rinnai Continuous Flow water heater products do not use a pilot light.
When installed and operated without water controllers, the opening of any hot water tap will
automatically start the appliance.
Once water is flowing through the appliance the burner will be ignited by electronic ignition.
When the hot water tap is closed and water flowing through the appliance has stopped the burner
flame will extinguish.
The Rinnai Continuous Flow water heater range other than the Rinnai Heavy Duty
(HD) series are factory pre-set to a temperature limit of 50°C or 55°C. The HD series
are factory pre-set to a temperature limit of 65°C. Other limits, lower or higher, are
available on request for the entire Continuous Flow water heaters range.
Temperature controllers are available to allow precise digital temperature control.
Controllers can be fitted at any time after installation of the hot water unit.
Heated water can be dangerous, especially for young children and the infirm.
Water temperatures above 50°C can cause severe burns instantly and may even
result in death.
Those most at risk are children, disabled, elderly and the infirm.
Hot water at 65°C (a very common hot water temperature in Australia) can
severely burn a child in less than half a second. At 50°C it takes five minutes.
ALWAYS......
Test the temperature of the water with your elbow before placing your child in the
bath, also carefully feel water before bathing or showering yourself.
Supervise children whenever they are in the bathroom.
Make sure that the hot water tap is turned off tightly.
CONSIDER.....
Installing child proof tap covers or child resistant taps (both approaches will
prevent a small hand being able to turn on the tap).
Setting your appliance at a maximum temperature of 50°C (Contact Rinnai
Australia).
NEVER…..
Leave a toddler in the care of another child. They may not understand the need
to have the water temperature set at a safe level.