For INF26EN60. Also, The document are for others Continuus models: INFINITY 32 REU-VR3237WG INFINITY 26 REU-VR2626WG INFINITY 26 PLUS REU-VRM2630WD INFINITY 26I REU-VR2632FFUG INFINITY 20 REU-VR2024WG INFINITY 16, REU-VR1620WG, INFINITY, ENVIRO 32, REU-KM3237WD, ENVIRO 26, REU-KM2635WD, V1500, REU-VR2426WB, V1200, REU-VR1620WB, HD250E, REU-VRM3237WC, HD200E, REU-VRM2632WC, HD200I, REU-VRM2632FFUC

Loading ...
Loading ...
Loading ...
launaM noitallatsnI12ailartsuA ianniR
GENERAL INSTALLATION INSTRUCTIONS
REGULATIONS
This appliance must be installed in accordance with:
Current AS/NZS3000, AS/NZS3500 and AS5601
Rinnai Installation Instructions
Local regulations and municipal building codes
Installation, Service and Removal MUST BE by an Authorised Person only.
APPLICABLE MODELS
These Installation Instructions apply to the following Rinnai Continuous Flow Water heater models:
* Denotes an internal model.
APPLIANCE LOCATION
(External Models)
This appliance is designed for ‘Outdoor’ Installation only. As such, it must be located in an above
ground open air situation with natural ventilation, without stagnant areas, where gas leakage and
products of combustion are rapidly dispersed by wind and natural convection.
This appliance must be mounted on a vertical structure with the water and gas connections on the
underside pointing downwards. For appliances installed on elevated structures or under floors specific
requirements apply. Refer to AS5601 Section 5 for details.
This appliance must not be used as a domestic spa or swimming pool heater.
Location of the appliance flue terminal must be in accordance with Section 5 and Figure 5.3 of
AS5601. Figure 5.3 is reproduced in the ‘Horizontal Flue Terminal Clearances’ section of these
instructions. Note that AS5601-2004 was current at the time of printing but may have been
superseded. It is the installers’ responsibility to ensure current requirements are met.
(Internal Models)
This appliance is designed for ‘Indoor’ installation only. It may be installed ‘Outdoors’ in an enclosure
if the requirements of AS5601 Section 5 are satisfied. An enclosure is defined as a compartment,
enclosed area or partitioned off space primarily used for the installing of the appliance. If installed in
an enclosure, either Internally or Externally, the location should be ventilated to allow gas to dissipate
and provision must be made for the safe disposal of any leaking water to a visible location.
This appliance must be mounted on a vertical structure with the water and gas connections on the
underside pointing downwards. For appliances installed in roof spaces or elevated structures specific
requirements apply. Refer to AS5601 Section 5 for details.
This appliance must not be used as a domestic spa or swimming pool heater.
Rinnai internal models described in this manual must use the coaxial Rinnai FF flue components. The
use of non Rinnai FF flue components may result in a dangerous situation and violates regulations.
The maximum FF flue length is 9 metres with a maximum of three 90 degree bends. Horizontal (wall)
or vertical (roof) terminals are available. For detailed information refer to ‘FLUEING FOR INTERNAL
MODELS’ on page 26.
This appliance must be located so that the flue terminal exits the building at a suitable point.
If a horizontal (wall) terminal FFWALLTERM is used, the location must be in accordance with Section
5 and Figure 5.3 of AS5601. Figure 5.3 is reproduced under ‘HORIZONTAL FLUE TERMINAL
CLEARANCES’ on page 24 of this manual.
If a vertical (roof) terminal FFROOFCOWL is used, the location must be in accordance with Section
5 of AS5601 and the ‘FLUEING FOR INTERNAL MODELS’ on page 26.
REU-VR3237WG
REU-VR2626WG
REU-VRM2630WD
REU-VR2632FFUG*
REU-VR2024WG
REU-VR1620WG
REU-VRM3237WC
REU-VRM2632WC
REU-VRM2632FFUC*
REU-KM3237WD
REU-KM2635WD
REU-VR2426WB
REU-VR1620WB
AS5601-2004 was current at the time of printing but may have been superseded. It is
the installer’s responsibility to ensure current requirements are met.
NOTE