Nota Bene: When carrying out these operations be
carefulnotoinclinetheappliancebymorethan45°;inany
case, once the castors have been assembled, wait at least one
hour before turning it on.
Draining the condensate water
The condensate can be drained in 2 ways:
a) Draining into the tank
The condensate can be drained directly into the tank.
With this draining system, when the tank is full, the applian-
ce stops and the screen displays the tank alarm .
When the tank is full, remove it as shown in g. 2 and empty
it into a sink or a bathtub.
When the operation is complete, put the tank back in correct-
lybeingcarefultopositionthehandleasshowingure3.
b) Continuous external draining
If you require the appliance to operate for a long period of
time without periodically emptying the tank we advise you
to set up continuous draining as follows:
Open the door on the side of the appliance and screw
the nozzle onto the tting, as shown in gure 4.
Insert a garden hose into the nozzle and lead the end of
thehosetoaoor-leveldrain.
Make sure the tank is inserted correctly.
• Makesurethehose isneverplaced ataheightabove
thelevelofthenozzle(g.5).Otherwisethewaterwill
continue to drain back into the tank.
Make sure there are no kinks in the hose.