Owner’s Manual 21
ENGLISH
Maintenance and Service
Common Problems and Solutions
Before calling for service, please review the following list of common problems and solutions.
The air conditioner is operating normally when:
You hear a pinging noise. This is caused by water being picked up by the condenser on rainy days or in
highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling
efficiency.
You hear the thermostat click. This is caused by the compressor cycle starting and stopping.
You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid
conditions or on rainy days. This water overflows and drips from the rear of the unit.
You hear the fan running while the compressor is silent. This is a normal operational feature.
The air conditioner may be operating abnormally when:
Problem Possible Causes What To Do
The air conditioner is
unplugged or not plugged
in completely
The fuse is blown/circuit
breaker is triggered
Power failure.
The current interrupter
device is tripped.
Air flow is restricted
TEMP Control set too
higher number.
The air filter is dirty.
The air conditioner was
just turned on.
The room may have been
hot.
Cold air is escaping.
Cooling coils are iced up
The cooling coils are iced
over.
• Make sure the plug is completely plugged into the
outlet
• Check the fuse/circuit breaker box and replace the
fuse or reset the breaker
• In the event of a power failure, set the power control
to OFF. When the power is restored, wait 3 minutes
to restart the air conditioner to prevent the
compressor from overloading
• Press the RESET button located on the power cord
plug. If the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
• Make sure there are no curtains, blinds, furniture or
other obstacles in front of the air conditioner
• Set the TEMP control to a lower number.
• Clean the filter at least every 2 weeks. Refer to the
“Maintenance and Service” section of the manual.
• After the air conditioner is turned on, you need to
give the air conditioner some time to cool the room.
When the air conditioner is first turned on
you need to allow time for the room to cool down.
• Check for open furnace floor resisters and cold air
returns.
• CLOSE the air conditioner vent
• See Ice appears on the air conditioner below
• Ice may block the air flow and obstruct the air
conditioner from properly cooling the room.
• Set the mode control at HIGH fan or high cool with
the high temperature.
The air conditioner
does not operate
at all
Air conditioner
does not cool
Ice appears on the
air conditioner.
Loading ...
Loading ...
Loading ...