16
Make Electrical Connections
1. Disconnect power.
2. Feed the power supply cable through the conduit connector
and into the terminal box.
3. Connect the green (or green/yellow) ground wire to the green
or yellow/green ground wire using UL listed wire connectors.
Tighten the screw on the conduit connector.
4. Connect the 2 white wires together using UL listed wire
connectors.
5. Connect the 2 black wires together using UL listed wire
connectors.
6. Replace the terminal box cover and secure with screw.
7. Reconnect power.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
A. Green or green and yellow
ground wire
B. White wires
C. UL listed wire connectors
D. Black wires
E. UL listed or CSA approved
conduit connector
F. Downdraft vent wiring
Check Operation
1. Push and hold the button on the top of the downdraft vent
for a few seconds. The retractable section of the downdraft
vent will rise and the blower will be able to start using the
control slider. Remove any protective film and use a stainless
steel cleaner to clean any remaining grease. Position the top
trim over the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information on ordering, see the “Assistance or Service”
section.
2. Slide the control slider on the side of vent to check the
operation and speed of the blower.
3. If the blower does not operate:
Check that filter or filters are pressed in as far as they
will go.
Check that the circuit breaker has not tripped or
a household fuse blown.
4. Connect vent system to blower. Vent system must end with
a wall or roof cap. Use clamps or duct tape to seal all joints.
5. Install cooktop according to manufacturer’s instructions.
Check that rear of cooktop overlaps edge of retractable
downdraft vent by
3
/
8
" (9.5 mm). See “Countertop Cutout
Dimensions” in the “Location Requirements” section.
NOTE: To get the most-efficient use from your new retractable
downdraft vent, read the “Vent System Use” section.
A
B
D
E
C
A. Top trim
B. On/Off button
C. Blower control slider
D. End cap
E. Filters