Install the air conditioner to the opening dimensions shown below.
Never install the unit where each of the air inlet is blocked.
The air conditioner should be installed with a strong external support to minimize noise and vibration,
and for the purpose of safe installation, repair, replacement and secure positioning.
Avoid installing the air conditioner where it is exposed to direct sunlight.
For safe, trouble free operation, connect the power cord of the unit to a properly rated
10 amp independent circuit with a time delay fuse or a circuit breaker.
More than 40 cm (16")
Air outlet
Air inlet
More than 20 cm (8")
Air inlet
Air inlet
Air inlet
More than 20 cm (8")
Air outlet
More than 40 cm
(16")
About 1 cm
(3/8")
Grounding tab
Plug
INSTALLATION INSTRUCTIONS
E-2
LOCATION
FUSE
WARNING: THIS APPLIANCE MUST BE GROUNDED.
This appliance is equipped with a cord having a grounding wire with
a grounding tab.
The plug must be plugged into an outlet that is properly
installed and grounded.
GROUNDING
ENGLISH
48.0~49.0 cm
(18 7/8"
~19 5/16"
)
8~20 cm(3"~8")
36.0~37.0 cm
(14 3/16"~14 9/16")
More than 20 cm (8")
More than 20 cm (8")