Loading ...
Loading ...
Loading ...
GAS WALL OVEN INSTALLATION INSTRUCTIONS
8
9.NaturalGasConversion
ConvertthePressureRegulatorforusewith
Natural Gas (see Figure 10)
A. Remove the cap from the pressure regulator.
B. Remove the plunger.
C. Turn the plunger around so that the small end is
TOWARDS the regulator.
Air Adjustment
Shutter
Loosen
Figure14
mately half open. For LP Gas, the air shutter nearly
full open.
Too much air will cause the ame to lift away from
the burner. Too little air will cause the ame to turn
yellow at the outer edges and soot to form.
Remember, the oven will be shipped from the fac-
tory set for Natural Gas, unless otherwise stated. If
connecting to LP gas, be sure to follow procedure
under "Conversion" to change the regulator and
burner orice to the LP setting.
Observe the oven burner ame to determine if it is
Figure13
Pin
L.P.
Nat.
Waist-High
Broiler Orice
Orice
Air Shutter
Using a ½" wrench, turn down the adjustable orice
which injects gas into the oven burner. Turn orice
approximately 2½ turns until snug against the LP
metering pin. Do not overtighten.
C.AdjustBroilerBurnerOrice(Self-Cleaning)
ModelsOnly)(see gure 13)
D. Replace the plunger inside the regulator. The
letters NAT or 4" W.C. should be visible on the
exposed end of the plunger.
E. Replace the cap on the pressure regulator.
F. Turn orice approximately 2½ turns counter-
clockwise. This will move the spud away from the
pin.
G. Apply gas, adjust pilots (if equipped) and burner
air shutter for proper ame.
H. There should be 4" WC pressure in the manifold
after conversion for proper operation on Natural
Gas.
10.Adjustments
Oven/BroilerFlameAdjustment
The air shutter adjustment is located on the venturi
tube, which sets on the orice of the valve, and
is locked in place with a Phillips head screw. If the
air shutter needs adjusting, loosen the screw and
rotate the shutter to allow more or less air to the
burner tube (see Figure 14).
For Natural Gas, the air shutter should be approxi-
Figure12
Pin
L.P.
Nat.
Air Shutter
Oven Burner Orice
Orice
Using a ½" wrench, turn down the adjustable orice
which injects gas into the oven burner. Turn orice
approximately 2½ turns until snug against the LP
metering pin. Do not overtighten.
Regulator
B.AdjustOvenBurnerOrice(see Figure 12)
Loading ...