Cabinet Requirements
IMPORTANT: If installing a range hood, hood liner, or microwave hood combination above the cooking surface, follow the range hood
or microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
Size A*
Cooktop Cutout to
Back Wall
B**
Cooktop to
Cabinet
C
Optional Backguard
and Upper Cabinet
Opening
D
Cabinet and
Countertop
E
Countertop Only
30" (76.2 cm) 1
3
4
" (4.4 cm)* 42" (106.7 cm) 30" (76.2 cm) 29
1
4
" (74.3 cm) 29
3
4
" (75.6 cm) for
zero clearance
36" (91.4 cm) 1
3
4
" (4.4 cm)* 58" (147.3 cm) 36" (91.4 cm) 35
1
4
" (89.5 cm) 35
3
4
" (90.8 cm) for
zero clearance
48" (121.9 cm) 1
3
4
" (4.4 cm)* 58" (147.3 cm) 48" (121.9 cm) 47
1
4
" (120.0 cm) 47
3
4
" (121.2 cm) for
zero clearance
*NOTE: If back wall is constructed of a combustible material and a backguard is not installed, a minimum clearance of
dimension A + 6" (15.2 cm) is required for all models.
If installing a range hood, hood liner , or microwave hood combination above the cooktop, follow the range hood, hood liner or
microwave hood combination installation instructions for dimensional clearances above the cooktop surface.
**If not using ventilation, Minimum Clearances
30" (76.2 cm) models: 42" (106.7 cm) minimum clearance between the top of the cooking platform and the bottom of a combustible
surface.
36" (91.4 cm) models: 58" (147.3 cm) minimum clearance between the top of the cooking platform and the bottom of a combustible
surface.
48" (121.9 cm) models: 58" (147.3 cm) minimum clearance between the top of the cooking platform and the bottom of a combustible
surface.
NOTE: Due to manufacturing factory tolerances, these are nominal dimensions. You may need to readjust to meet your clearance.
A
B
C
D
A. Grounded 3 prong outlet should be located on
left-hand side of the cutout 16" (40.6 cm) max.
from enclosure sidewall
B. 10" (25.4 cm) min. clearance from countertop to
top of the outlet
C. 14" (35.6 cm) countertop to the gas supply line
D. Gas supply line should be located in this area on
rear or side walls or the supply line can come up
through the oor.
NOTE: Solid side and bottom of cutout enclosure
not shown.
B min.
C
A*
D
E
F
I
J
K
M
G
N
O
H
C
E
L
P
L
D
A. See chart.
B. See chart.
C. See chart.
D. See chart.
E. See chart.
F. 18" (45.7 cm) min. clearance upper cabinet to
countertop
G. 3/4" (19 mm) back of cabinet cutout to gas
opening cutout
H. 6
7
8
" (16.1 cm) gas opening cutout depth
I. 12
1
2
" (31.7 cm) gas opening cutout width
J. 22
1
4
" (56.5 cm) cabinet cutout depth
K. 2" (5.1 cm) cabinet side to gas cutout
L. 12" (30.4 cm) min. distance on both sides of the
cooktop to the side wall or other combustible
material above cooking surface
M. 24" (61.0 cm) cabinet depth
N. 7
1
4
" (18.4 cm) cabinet depth to countertop
O. Notch to be equal on both sides
P. 13" (33.0 cm) upper cabinet depth