TROUBLESHOOTING
You can solve many common BeautiFridgeâ„¢ problems easily, saving you the cost of a possible
service call. Try the suggestions below to see if you can solve the problem before calling a service
technician.
Problem
Possible causes
Ways to solve problem
The unit does not
operate.
The plug is badly
connected, or the
fuse is burned out.
Unplug the power cord and re-connect the
plug to the power supply, or replace the fuse.
Abnormal operation of the
compressor, or the
compressor makes a
buzzing sound.
The power voltage is
out of the rated
range.
Disconnect the power supply immediately and
reconnect with it after normal voltage has
been supplied. It is necessary to have a
voltage stabilizer in case of poor power
supply.
The compressor operates
too long and no frost on
the surface of the
evaporator
Refrigeration system
is at fault (leakage or
blocked).
Call for service
There is frost or ice on
the walls of the inner
cabinet.
The internal temperature
is too low, and the
compressor never stops
running.
The thermostat does
not work.
Call for service
The temperature
setting of the
thermostat is too low.
Adjust the thermostat to a lower temperature.
The internal temperature
is too high, and the
compressor never stops
operating.
Bad heat dissipation
and ventilation of
condenser.
Improve the ventilation.
Too many warm
items loaded into the
unit in at one time.
Remove some food/beverage so air can
circulate
The door is being
opened too
frequently.
Permit the unit to cool down to the thermostat
temperature; prevent opening the unit during
this phase.
The unit makes too much
noise.
The unit is not level.
Adjust the adjustable legs.
The fastener of the
unit is loose.
Tighten the loose fastener.
Pipes near the
compressor are
touching.
Carefully separate the pipes.
NOTE: All repairs must be carried out by qualified authorized personnel. Inadequate repairs may be
dangerous. Never try to repair the cooler yourself.